Program
Display
Code
FC-37
COOK MODE AUTO MIX:
NORMAL FILL TIME
FC-38
COOK MODE AUTO MIX: FILL:
NO DETECT: MAX PUMP
FC-39
COOK MODE AUTO MIX: DE-
SIRED BOTTOM TEMP
FC-40
COOK MODE AUTO MIX: MIN
REQUIRED OIL TEMP
Description
The expected time it takes to refill the vat at
the end of an auto mix operation.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
If the fryer pumps for this amount of time dur-
ing the FILL phase without observing a tem-
perature rise on the upper temperature
probe, the control turns the pump off, and
asks IS POT FILLED?. If pot is not filled com-
pletely, press NO and the pump will attempt
to fill further.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
The purpose of the Cook Mode Auto Mix op-
eration is to attempt to keep the bottom of
the pot hot enough that crumbs don't stick.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
This is the minimum oil temperature required
in order to activate an Auto Mix operation.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.