SP-18
SP-19
SP-20
SP-21
SP-22
SP-23
SP-24
72
Display Name
BULK OIL
Press the plus or minus button to select either YES,
SUPPLY?
NO, or YES+BSV to indicate if a bulk oil supply is avail-
able for refilling the ATO oil tank and vat with fresh oil.
COOKING: SHOW
Press the plus or minus button to select YES or NO to
PSI?
display the live pressure reading (in PSI) on the bottom
line of the control board during the cook cycle for pres-
sure fryers only.
CHANGE MGR
Provides access to change the Manager password
CODE
code, which is defaulted to 123 from the factory. The
manager password code is used to access modes such
as Product, Cook, Special Programming, etc.
CHANGE USAGE
Provides access to change the Reset Usage password
CODE
code, which is defaulted to 123 from the factory. The
Reset Usage password code is used to access the
usage statistics, it does not grant any programming
privileges.
CLEAN-OUT TYPE
The Clean-Out function supports two different water
based clean-out modes, Heated and Cold-Soak.
Heated is heated and timed while Cold-Soak is un-
heated and not timed. KFC software is hard-coded for
Cold-Soak only, it cannot be changed.
CLEAN-OUT TEMP
CLEAN-OUT
MINUTES
Function
24V=OK - 24V signal on DTF wires means it is OK
to pump. No signal means the tank is full (do not
pump).
If Heated mode is selected in the SP-22 menu,
operators may select a temperature between 40°F
– 195°F with which to heat the water. Higher
temperatures require Personal Protective
Equipment (PPE) to prevent burns.
If Cold-Soak mode is selected in the SP-22 menu,
this setting displays Cold-Soak and can not be
changed.
If Heated mode is selected in the SP-22 menu,
operators may select a time 1 Min. to 99 Min. The
timer starts after the water is heated to the
temperature selected in SP-23. The clean cycle
time allows the amount of time necessary to scrub
the vat and lid before prompting to drain and rinse.
If Cold-Soak mode is selected in the SP-22 menu,
this setting displays Cold-Soak and can not be