FC-17
POLISH: FILL: NO DETECT:
MAX PUMP
N N O O T T E E : If X pulses of oil have not brought the level up, the control assumes that the oil tank
is empty—that no oil is being pumped into the pot—and displays FILL OIL TANK. If the fryer
is configured to use a Bulk Oil Supply system, the message displayed is CHECK BULK OIL
SUPPLY rather than FILL OIL TANK. In this case, it is possible that the remote bulk supply
tank is empty, that the bulk supply plumbing connection is not connected to the fryer, or that
the bulk supply electrical connection is not connected.
FC-18
AUTO TOP OFF: ENABLED?
times this expected time, the SLOW FILLING
warning is activated, alerting that the fryer is
pumping more slowly than expected.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
If the fryer pumps for this amount of time dur-
ing the FILL phase without observing a tem-
perature rise on the upper temperature
probe, the control turns the pump off, and
asks IS POT FILLED?. If pot is not filled com-
pletely, press NO and the pump will attempt
to fill further.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
A A u u t t o o T T o o p p O O f f f f S S e e t t t t i i n n g g s s
Enables or disables all Auto Top Off (ATO)
operations.
1 1 . . Press the + or - button to select either
YES or NO.
Disabling the Auto Top Off feature would nor-
mally be done only if the top off system itself
has failed, in order to avoid the FILL OIL