Download Print this page

Henny Penny Velocity Series Operation Manual page 77

Hide thumbs Also See for Velocity Series:

Advertisement

Menu Item
Function
(Digital) Inputs-
✓ - Signal present
2
- - No signal present
24dc - 24 DC Supply
Pan - Filter Drain Pan
*Lid - Lid Liner Pin
Lid Liner Pin shows OK if pin is down
Lid Liner Pin shows PR when pin is raised (under pressure)
(Bulk Oil) In-
✓ - Signal present
puts-3
- - No signal present
DTF - Discard Tank Full
FULL - Discard tank is full and cannot dispose to it
OK - Discard tank not full, okay to dispose
Pressure Inputs
Displays reading from the pressure transducer as:
OK - Safe to open lid (not under pressure)
PR - Lid under pressure, cannot open
Manifold
Displays pump pressure reading if optional transducer is installed in
Pressure
plumbing manifold as:
* - On
- - Off
otherwise displays NO SENSOR.
Fryer Outputs
* - On
- - Off
Pri - Primary Contactor
Ht - Heat (regulating) Contactor
Pr - Pressure Solenoid
BSV - Bulk Supply Valve (optional)
Drain Valve
Par - Partially open
(Control) Status
Stp - Forced Stop
Opn - Fully Open
Cls - Fully Closed