Menu Item
Function
(Digital) Inputs-
•
✓ - Signal present
2
•
- - No signal present
•
24dc - 24 DC Supply
•
Pan - Filter Drain Pan
•
*Lid - Lid Liner Pin
–
Lid Liner Pin shows OK if pin is down
–
Lid Liner Pin shows PR when pin is raised (under pressure)
(Bulk Oil) In-
•
✓ - Signal present
puts-3
•
- - No signal present
•
DTF - Discard Tank Full
•
FULL - Discard tank is full and cannot dispose to it
•
OK - Discard tank not full, okay to dispose
Pressure Inputs
Displays reading from the pressure transducer as:
•
OK - Safe to open lid (not under pressure)
•
PR - Lid under pressure, cannot open
Manifold
Displays pump pressure reading if optional transducer is installed in
Pressure
plumbing manifold as:
•
* - On
•
- - Off
otherwise displays NO SENSOR.
Fryer Outputs
•
* - On
•
- - Off
•
Pri - Primary Contactor
•
Ht - Heat (regulating) Contactor
•
Pr - Pressure Solenoid
•
BSV - Bulk Supply Valve (optional)
Drain Valve
•
Par - Partially open
(Control) Status
•
Stp - Forced Stop
•
Opn - Fully Open
•
Cls - Fully Closed
67