Problem
Foaming or boiling
over.
Oil not draining.
Filter motor won't
run.
8 8 . . 3 3 E E r r r r o o r r C C o o d d e e s s
In the event of a system failure the control board displays an error message. These
messages are coded as E which represents an error, a number designation and error
message, such as E-4 CPU TO HOT. Also, a constant tone sounds. To silence the
tone, press any of the product buttons. Use the following table to interpret and correct
an error code.
Error
E-1 LOW
OIL IN
POT
E-4 CPU
TOO HOT
E-5 OIL
TOO HOT
90
Cause
Some customers choose not
to use oil stabilizers which
can cause foaming and boil-
over.
See boil-over chart on fryer
and Boil-Over Prevention
section of Operator's Manual.
Drain valve clogged.
Motor overheated.
T T a a b b l l e e 8 8 - - 2 2 E E r r r r o o r r C C o o d d e e s s
Cause
The top heating ele-
If the Protection Probe monitoring function determines
ment where the
that the oil level is too low—below the main probe—it
probe is located is
generates an E-1 error code and displays the message
getting hotter than it
LOW OIL IN POT!, CHECK OIL LEVEL. Fill the vat with
would if the element
oil to the full line. If the error persists call for service.
were submerged in
oil.
Control board
Remove heat from the fryer, the control board is getting
overheating.
too hot. Once the front panel cools down the controls
should return to normal operation. If the error persists
call for service.
Oil overheating.
Remove heat from the fryer. Once the unit cools down,
the controls should return to normal operation. If the er-
ror persists call for service.
Correction
Product with excessive ice crystals
should be dipped once quickly then
removed from the fryer to allow ice
crystals to melt and excessive water
to evaporate. Then place the product
back into the fryer and cook
normally.
Refer to 2.7 Boil-Over Prevention in
the Operator's Manual.
Push cleaning rod through open
drain valve.
Reset motor. Refer to Filter Pump
Motor Protector - Manual Reset sec-
tion of Operator's Manual.
Correction

Advertisement

loading

This manual is also suitable for:

Pxe-100