Program
Display
Code
FC-10
DAILY FILTER + POLISH: FILL:
DETECT AT LEVEL PROBE,
KEEP PUMPING
FC-11
DAILY FILTER: FILL: NO DE-
TECT: MAX PUMP
N N O O T T E E :
For very thin (low viscosity) cooking oils, drain opening setting may need to reduce from
the default value and you might need to reduce the drain opening setting from the default
value.
For 50 Hz systems, or if the control routinely gives up before the pot is refilled, you might
need to increase the max pump time from the default value–50 Hz pumps may run more
slowly than 60 Hz pumps.
Description
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
When refilling the pot, specifies how long to
keep pumping after the oil reaches the upper
probe and the expected temperature rise is
observed.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
If the fryer pumps for this amount of time dur-
ing the FILL phase without observing a tem-
perature rise on the upper temperature
probe, the control turns the pump off, and
asks IS POT FILLED?. If pot is not filled com-
pletely, press NO and the pump attempts to
fill further.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
P P o o l l i i s s h h S S e e t t t t i i n n g g s s