Menu Item
Selector Valve
(Bulk Oil Fryers
Only)
Pump Outputs
Analog Inputs
Memory (Sta-
tus) Info (Infor-
mation) (MEM
INFO)
USB Drive Sta-
tus (USB INFO)
68
Function
•
► - The current state of the drain valve
•
At - indicates the drain valve position
–
0 - Fully Closed
–
20+ - Fully Open
Displays in the lower right with the current port position as:
•
No Selector Valve - unit is not equipped with a Bulk Oil System
•
E=001 - Encoder Position
Displays in the lower left with the activity of the valve as:
•
STPD - Stopped
•
FWD - Forward
•
REV - Reverse
•
* - On
•
- - Off
•
Fltr - Filter Pump
•
ATO - Top Off Pump
•
Bulk - Bulk oil Supply
Displays analog input readings directly from ADC chip displayed as volts
and as ADC counts (bits). Use the up and down arrows to step through
available inputs.
Displays the status and size of the control's internal microSD storage
memory as:
•
✓ - Memory OK
•
X - Memory problem
If installed, displays the status and size of the USB flash drive as:
•
✓ - Flash Drive OK
•
X - Flash Drive not present or drive error
•
hcc - 16 is normal if no USB drive is plugged in
Scroll down to see flash drive volume name.