Tension Regulator Band Assembly Replacement - Sony Betacam SX DNV-5 Maintenance Manual

Hide thumbs Also See for Betacam SX DNV-5:
Table of Contents

Advertisement

3-2-7. Tension Regulator Band Assembly Replacement

3-2-7. Tension Regulator Band Assembly Replacement
Outline
Replacement
Tension regulator band assembly removal
Reel table cleaning
Tension regulator band assembly installation
Adjustment after replacement
Tension regulator operating position adjustment
FWD back tension adjustment
Tape running confirmation
Precaution
Replace the tension regulator band assembly itself if the felt surface of the tension
regulator band assembly is hardened or worn.
Preparations
1. Confirm that the unit is in the unthreading end state.
2. Turn off the power.
3. Remove the front lid and outside panel.
(Refer to section 1-6 in Part 1 of the Maintenance Manual.)
4. Remove the cassette compartment.
(Refer to section 3-3-24.)
n
Stop washers are used for installation of the tension regulator band assembly. Do not
reuse them. Install the new ones (3-559-408-11) when replacing the tension
regulator band assembly.
Tools
. Stop washer fastening tool
. Cleaning cloth
. Cleaning fluid
3-34
J-6323-530-A
3-184-527-01
9-919-573-01
DNV-5