Sony Betacam SX DNV-5 Maintenance Manual page 30

Hide thumbs Also See for Betacam SX DNV-5:
Table of Contents

Advertisement

2-1. Setup Menu
Viewfinder screen (Factory default setting)
* WHT PRESET *
R WHT PRESET
: 0
B WHT PRESET
: 0
* TG ADJ. *
BC COMP. ADJ.
: 0
BC COMP.
: ON
FLD/FLM
: FLD
TEST OUT
: ENC
* VA ADJ.-1 *
R GAIN (TMP)
: 0
G GAIN (TMP)
: 0
B GAIN (TMP)
: 0
R MOD BAL.
: 0
G MOD BAL.
: 0
B MOD BAL.
: 0
SAW/REC
: SAW
TEST LEVEL
: 0
TEST SAW
: OFF
2-16
Description
........... Used for the manual adjustment when the white balance memory is preset.
Sets the FILTER selector to 1 (3200 K), shoots the light source (pattern box) of
the required color temperature, and sets the levels in channels R and B so that
the white balance is adjusted.
........... F data (Never attempt any adjustment.)
........... F data (Never attempt any adjustment.)
........... Sets the CCD read system.
FLD : Field read mode. Usually, set to FLD.
FRM : Frame read mode. This position is selected when improved vertical
resolution is desired.
n
The frame read mode has more image lag than the field read mode.
This item is the same as the "FIELD/FRAME" item on the "FUNCTION 2/2"
page.
........... Sets the type of the video signal output from the TEST OUT connector.
This item is the same as the "TEST OUT" item on the "FUNCTION 1/2" page.
........... Sets the gain of the white balance amplifier temporarily. (For circuit operation
check purpose during maintenance)
This value is automatically rewritten by adjusting the white balance, selecting
the WHITE BAL (white balance memory) switch, changing the ND/CC filter
setting. The gain of the white balance amplifier can be directly set by setting the
R, G, and B values. However, are temporary values, and rewritten by adjusting
and changing the setting as described above.
........... Used for the modulator balance adjustment. (For circuit operation check
purpose during maintenance)
The modulation balance is automatically adjusted by performing the modulator
balance adjustment (Section 8-6). During manual adjustment, the manually
adjusted value is written in EEPROM instead of the automatically detected
value.
........... Selects the waveform output when the "TEST SAW" item is set to ON.
SAW : Test sawtooth wave
REC : Rectangular wave
........... Adjusts the gain of the test waveform.
The peak level is automatically adjusted so that the test sawtooth wave and
rectangular wave are the same in a level.
........... Closes the lens forcibly and sets whether to add the test sawtooth waveform to
the video signal system.