2-1. Setup Menu
Switch description
1. MENU switch
OFF
: Terminate the SETUP menu.
Usually, set to OFF.
ON
: Execute the SETUP menu.
PAGE
: Search page of the SETUP menu.
CANCEL/PRST: Cancel the setting value (during level control) or reset to the factory-setting value.
ITEM
: Select item.
2. Rotary encoder
Rotary encoder uses to change the set value of selected item or to decide the changed setting value.
Operation
The SETUP menu is set to the USER mode when shipped from the factory.
Perform the following procedures to enter the SVC mode.
1. Turn the main power off.
2. Set the switch S4-1 on the DCP-1 board to ON.
3. Turn the main power on.
4. Set the MENU switch to ON. The SETUP menu appears on the viewfinder screen.
Setting Change (MENU switch operation)
1. To select the page, throw the MENU switch to PAGE. The page will be shifted to the next page every time the switch
is thrown to PAGE.
2. To select the item, throw the MENU switch to ITEM. The cursor pointing the item will be shifted to the next item
every time the switch is thrown to ITEM. By pressing the rotary encorder, selected item is entered.
3. To change the setting value, turn the rotary encoder.
4. To exit from the SETUP menu, set the MENU switch to OFF.
Setting Change (Rotary encorder operation)
1. To select the page, turn the rotary encoder until the desired page is appeared and press it down.
2. To select the item, turn the rotary encoder until the cursor pointng the item is shifted to the desired item and press it
down.
(When pressing the rotary encoder down with the cursor pointing the title of item, the menu display will be returned to
the state in procedure 1.)
3. To change the setting value, turn the rotary encoder.
4. When pressing the rotary encoder down again, the menu display will be returned to the state in procedure 2
5. To exit from the SETUP menu, set the MENU switch to OFF.
n
When the unit is externally controlled by the remote control unit RM-P9, some functions cannot be controlled. (Refer to