USE OF T&A (Torque & Angle)
Choose the T & A mode (see point 26: Modify function on the program menu)
It is possible to set 6 different modes:
 TORQUE (Torque): It's the most common use mode. The control unit shows the tightening torque and
the torque starting from a certain torque percentage (threshold torque, see point 27). If the final torque
and angle values are within the preset minimum and maximum values, the screw is correctly tightened.
If the torque and/or angle are outside the preset values, the screw will be considered as incorrectly
tightened. In this case the red led will light up and the message "Error Max (Min) Angle" or "Error Max
(Min) Torque" will be displayed.
 TORQUE/INPUT (T/IN): It corresponds to Torque mode, except for the threshold torque which
can't be set by the operator: in fact the value is the result of an external impulse through a proper
contact (see paragraph "connections"). It can be very useful if the operator wants the control unit to
start counting the angle from a position which is indicated by a precision instrument.
 TORQUE/LEVER (T/LV): No threshold is preset by the operator: the angle value that appears on
the display corresponds to the angle that is carried out starting from the moment in which the lever
is pressed until the torque is reached.
 ANGLE (Ang.): This mode gives priority to the angle to be reached. The value is measured starting
from a tightening torque percentage.