"Error max angle" is displayed on the status bar
11
(The max preset angle has been reached. Only
available in Tor, T/lv and T/in mode).
"Error angle not OK" is displayed on the status bar
12
(The preset angle hasn't been reached. Only
available in Ang., A/lv and A/in mode).
"Warning! No piece" is displayed on the status bar
13
(The "missing piece" contact is enabled).
"Compensation error" is displayed on the status bar.
14
A negative torque value is displayed due to a high
negative compensation value.
"Released lever error" is displayed on the status bar
15
(The lever has been released while tightening).
"Reverse torque error" is displayed on the status
16
bar (The torque signal is displayed while
loosening, but only if it's set on "max").
"Output Disabled". Protection of output signals was
17
activated after exceeding maximum load (400mA).
"Protection 12A" is displayed on the status bar (it
18
happens when current on mosfets of bridge H is >
12 A for at least 1 s)
"Protection 14p5A" is displayed on the status bar (it
19
happens when current on mosfets of bridge H is >
14.5 A for at least 800 ms)
"Protection 15A" is displayed on the status bar (it
20
happens when current on mosfets of bridge H is > 15
A for at least 500 ms)
ATTENTION: IF THE OK/ESC OPTION IS DISABLED, ERRORS RESET AT THE
FOLLOWING SCREW/PROGRAM. OTHERWISE PRESS ESC. IF THE PROBLEM PERSISTS,
PLEASE CONTACT YOUR NEAREST KOLVER DEALER.
Vers. 211020
-check contact 2 on the CN2 connector
- increase or decrease the compensation value
Such error can be enabled or disabled
through "PROGRAM-MENU" (see point 18
on the program menu).
- The screwdriver couldn't loosen
- Avoid motor stalling
- Loosening too heavy
- Check the set load is not over the allowed
maximum value
- Restart the control unit to reset error
- Decrease screwing time and check settings
- Avoid motor stalling
- Unscrewing too heavy
- Joint too soft
- Decrease screwing time and check settings
- Avoid motor stalling
- Unscrewing too heavy
- Joint too soft
- Decrease screwing time and check settings
- Avoid motor stalling
- Unscrewing too heavy