Powering up the cabinet
Initial power up
To apply initial power to the cabinet:
1.
2.
3.
4.
5.
Inst. 7–12
CAUTION
When the two LEDs of the CTU, or the MCUF are flashing,
the boot code is downloading into non-volatile memory for
software upgrade. Do not remove power or reset the
cabinet until downloading has been completed, as this will
corrupt the non-volatile memory. If the boot code is
corrupted, contact Motorola Customer Network Resolution
Centre and request the boot code restoration procedure
and the appropriate boot code file.
Switch on the external power supply to the cabinet.
Set the four pole MCB and the 6 A RCBO, in number 1 ac distribution box,
to on.
Set the TMS fans circuit breaker on the PSU dc circuit breaker panel to
on.
Set the TMS heater and TOPSM circuit breakers, in the number 2 ac
distribution box to on. Check that input healthy (yellow) and output healthy
(green) LEDs of each TOPSM illuminate as it is switched on. Check that
the radio and comms contactor LEDs on the CAB are illuminated.
Carry out a test of the TMS as described in Testing the thermal
management system (TMS).
Installation & Configuration: Horizon macro outdoor
68P02902W03-A
CONTROLLED INTRODUCTION
GSM-204-423
31st Oct 01