BTS architectures and interoperability
Horizon macro combining
A similar arrangement is used in the Horizon macro , which uses a Hybrid
Combiner Unit (HCU) and Dual stage Duplexed combining Filter (DDF), as
shown in Figure 6-7. The DDF has three input ports together with two internal
RF loads, and therefore does not require the addition of any external load.
Inst. 6–8
HCU
Load
Hybrid
Carrier 1
One carrier from each of four transceivers
Figure 6-7 Typical Horizon macro arrangement for combining four carriers
Installation & Configuration: Horizon macro outdoor
68P02902W03-A
CONTROLLED INTRODUCTION
DDF
Carrier 2
Carrier 3 Carrier 4
GSM-204-423
Duplexer
Load
Hybrid
Load
Hybrid