Motorola Horizonmacro outdoor Installation/Configuration Manual page 181

Table of Contents

Advertisement

GSM-204-423
Commissioning overview
Overview of
commissioning
This chapter provides information required for the commissioning of cabinets
and their internal and external interfaces.
All site preparation (Chapter 2) and equipment installation (Chapter 3) must be
completed before commissioning. Commissioning consists of the following:
S
S
S
PC to MCUF
cable pin
connections
Figure 7-1 shows the pin connections for the personal computer (PC) to MCUF
test cable. These are standard null modem pin connections.
31st Oct 01
NOTE
Some equipment at the site may not be produced by
Motorola, including power supplies, customer
communications equipment and antennas. Refer to site
specific documentation and the non-Motorola vendor
instructions.
Pre-power up checks.
Powering up the cabinet.
Optimization procedures as described in Installation and Configuration:
BSS Optimization (GSM-100-423) 68P02901W43 , issue G or later.
PIN NUMBER
1
6
4
3
2
5
8
7
9
TO PC COMMUNICATIONS PORT
9-WAY D-TYPE MALE
Figure 7-1 9-way to 9-way PC to MCUF cable pin connections
Installation & Configuration: Horizon macro outdoor
68P02902W03-A
CONTROLLED INTRODUCTION
4 m LONG SCREENED CABLE
Commissioning overview
PIN NUMBER
4
6
1
2
3
5
7
8
9
TO MCUF TTY PORT
9-WAY D-TYPE FEMALE
Inst. 7–1