GSM-204-423
Configuration
for 2 cabinet
sector 5/5 or 6/6
Figure 3-24 shows a suggested configuration, using two Horizon macro cabinets,
for sector 5/5 or 6/6 with dual stage duplexed combining filter and air combining.
Unused SMA connectors must be fitted with 50 ohm terminating loads as shown
below.
31st Oct 01
CABINET 2
Figure 3-24 Two cabinet sector 5/5 or 6/6 with DDF and air combining
If configured for...
sector 5/5
Installation & Configuration: Horizon macro outdoor
68P02902W03-A
CONTROLLED INTRODUCTION
Suggested RF configurations
CABINET 1
(master)
Then 50 ohm load required on
unused SMA input to...
both DDF 2 modules
Inst. 3–47