GSM-204-423
ICS connector
Table 3-13 lists the Integrated Cell Site (ICS) connector pinouts. This is a future
feature.
31st Oct 01
Table 3-12 PIX1 pin connections (37-way D-type)
Pin
Signal/Description
no.
1
Site input Ext 9–1
2
Site input Ext 10–1
3
Site input Ext 11–1
4
Site input Ext 12–1
5
Site input Ext 13–1
6
Site input Ext 14–1
7
Site input Ext 15–1
8
Site input Ext 16–1
9
Not connected
Pins 10 to 18 not connected
Table 3-13 ICS pin connections (25-way D-type)
Pin
Signal/Description
no.
1
ICS0 TTY earth
2
ICS0 TTY Rx
3
ICS0 TTY Tx
4
ICS1 TTY earth
5
ICS1 TTY Rx
6
ICS1 TTY Tx
7
ICS2 TTY earth
8
ICS2 TTY Rx
9
ICS2 TTY Tx
Pins 19 to 25 not connected
Installation & Configuration: Horizon macro outdoor
68P02902W03-A
CONTROLLED INTRODUCTION
Interface panel cabling
Pin
Signal/Description
no.
19
Not connected
20
Site input Ext 9–2
21
Site input Ext 10–2
22
Site input Ext 11–2
23
Site input Ext 12–2
24
Site input Ext 13–2
25
Site input Ext 14–2
26
Site input Ext 15–2
27
Site input Ext 16–2
Pins 28 to 37 not connected
Pin
Signal/Description
no.
10
ICS3 TTY earth
11
ICS3 TTY Rx
12
ICS3 TTY Tx
13
ICS4 TTY earth
14
ICS4 TTY Rx
15
ICS4 TTY Tx
16
ICS5 TTY earth
17
ICS5 TTY Rx
18
ICS5 TTY Tx