Suggested RF configurations
Configuration
for 2 cabinet
sector 3/3/3 or
4/4/4
Figure 3-27 shows a suggested configuration, using two Horizon macro cabinets,
for sector 3/3/3 or sector 4/4/4 with duplexed combining bandpass filter and air
combining.
Unused SMA connectors must be fitted with 50 ohm terminating loads as shown
below.
Inst. 3–50
CABINET 2
Figure 3-27 Two cabinet sector 3/3/3 or sector 4/4/4 with DCF and air
If configured for...
sector 3/3/3
2/2/2 (depopulated 4/4/4)
Installation & Configuration: Horizon macro outdoor
68P02902W03-A
CONTROLLED INTRODUCTION
CABINET 1
(master)
combining
Then 50 ohm load required on
unused SMA input to...
cabinet 1, DCF 1
cabinet 2, DCF 0 and DCF 2
all Tx modules from
radio slots 1, 3, and 5