12A
ELECTRICAL COMPONENTS: FE400, KEY-START ENGINE
Battery Storage, Continued:
6. The frequency of recharging required depends on the temperature of the storage area, but it is recom-
mended that the battery be monitored for state of charge every month. Also, if the storage area is
unheated in a cold climate and recharging is required, it is recommended that the area be heated to at
least 60 °F (16 °C) prior to charging. The battery will not charge effectively in cold temperatures for the
same reasons that it does not discharge as rapidly in cold temperatures.
Charging a Dead Battery
Read DANGER and WARNING on page 12a-1 and DANGER on page 12a-33.
The vehicle is equipped with a starter/generator. The generator is not designed to charge a dead battery. If the
vehicle battery has become discharged, it must be charged using a properly rated automotive type charger.
See following WARNING.
WARNING
• Do not jump-start a dead battery using another battery and jumper cables.

GROUND CABLES

Testing the Ground Cables
See Test Procedure 3, Section 11a, Page 11a-25.
Page 12a-38