RSTI-EP PROFINET I/O Controller User Manual
GFK-2571R
7.1.3

SNMP Read Access

SNMP provides standard commands that allow a client to read SNMP data. The PROFINET
Controller supports these commands:
GET
GETNEXT
GETBULK
The SNMP Community strings supported for read access are:
public
pub
icmp
private
priv
ge_pnc
These community strings are fixed and cannot be changed.
7.1.4

SNMP Write Access

SNMP should not be used to change parameters on the PROFINET Controller module.
For PNC001 firmware version 2.05 and earlier, the SNMP SET command succeeds for
the variables in some MIBs/groups but fails for the variables in other MIBs/groups.
Changes made using SNMP SET change only the SNMP variable itself, do not affect the
PNC001 module operation, and are not saved across a power-cycle or restart. For
example, setting the sysName variable from the System Group does not change the
Device Name of the PNC001 module.
The SNMP Set command for PNC001 firmware version 2.10 and later is disabled
7.1.5

MIB-II Groups Supported

The PROFINET Controller supports all the mandatory values in the following groups of the
MIB-II specification:
System group
Interfaces group
IP group
ICMP group
18
Requires PNC firmware version 2.05 or later.
19
Requires PNC firmware version 2.10 or later.
Network Management
18
18
18
18
18
19
Section 7
May 2021
145