Advertisement

Program execution screen
Machines with gas heating
Giving the start order (pressing the START
key) starts the roll rotation and the
activation sequence of the heating system.
When the roll temperature is 10º C (18º F)
below the programmed temperature (PT),
an acoustic warning sounds indicating that
the system is ready for linen to be inserted.
CAUTION!
Purge time.
The burner lights up after a safety period
has passed.
During the execution of a program, the
keys
and
on the control panel
allow the burner to be turned on and off.
Interpreting
the
program
screen:
A- TP. Programmed temperature
B- Ironing temperature
As long as the roll temperature is not
10ºC
lower
than
temperature,
it
will
flashing.
C- Indication of the heating status
D- Roll speed
E- Folder functioning mode and length of
programmed item
F- Length of last article inserted
G- Program identification
H- System clock
MOD key: makes it possible to modify the parameters of the program running.
EXPULS key: activates the expulsion straps.

7.5.2. Stopping the program

Pressing once on the
The ironer enters a cooling situation: the rotation speed is reduced and the extractor fan is kept running while
the roll temperature exceeds 100º C (202º F).
When the temperature falls below this value, the rotation of the roll is halted, the extractor halts and the main
menu icons are displayed on the screen.

7.5.3. SHUT DOWN mode

This is an option available on machines with a folder or a photoelectric cell beam fitted and properly
programmed in the SETUP menu.
Operation
If 20 minutes go by without the ironer detecting linen being fed in, it enters a cooling cycle.
Once the cooling is complete (a temperature below 100º C/212º F) the machine stops.
Select a new ironing program to exit SHUT DOWN mode.