5.3.1. CE certified models

Gas type change label
THIS
EQUIPMENT
YEAR)............(1)...........
....(3)......BY............(4).....................
(name and address of organization making this conversion, who accepts the
responsibility for the correctness of this conversion).
PRESSURE
CONSUMPTION (PROPANE GAS)
NOMINAL HEAT CONSUMPTION (Hi)
ORIFICE (DIAMETER)
Gas type change label fields
(1) Date of the change
(2) Type of gas the ironer is to be changed to
(3) Code of the gas change kit
(4) Organisation, company or ATS that has carried out the change.
(5) Gas supply pressure
(6) Massic consumption; models supplied with propane gas
(7) Volumetric consumption; models supplied with natural gas
(8) Nominal calorie cons. with regard to H
(9) Injector diameter.
Refer to the machine's parts list for the codes of the various conversion kits.
See Section 4.3 for values of fields 5, 6, 7, 8 and 9.
Steps for the connection
WAS
TO......(2)..........
........................................................................
(NATURAL GAS)
.........................................
...................................................... (9) ......................... mm
i
CONVERTED
ON
GAS
WITH
(5)
.........................
................................ (6) ......................... kg/h
(7)
.........................
.......................... (8) ......................... kW
(DAY-MONTH-
KIT
No
mbar
3
m
/h
Code no. 550038
Rev. no. 16/1018
63