7.3. Stop modes

7.3.1. Normal machine stopping

STOP
PRESS
KEY. The heating system is turned off. The ironer enters a cooling situation: the rotation speed
is reduced and the extractor fan is kept running while the roll temperature exceeds 100º C (212º F).
When the temperature falls below this value, the rotation of the roll is halted, the extractor halts and the main
menu icons are displayed on the screen.

7.3.2. General Stop

Disconnecting the mechanically lockable isolator switch, located on the base-frame side cover. COMPLETELY
disconnects the machine from the power supply. Its use is recommended for maintenance interventions and in
situations of prolonged machine stoppage.
Mechanically locking switch breaker
Set the switch breaker at the " 0" position.
Fit a padlock on the opening to prevent the switch breaker being handled by others.
CAUTION!
ONCE THE SWITCH BREAKER HAS BEEN MECHANICALLY LOCKED, OPENING THE SAFETY GUARD
IS NO LONGER POSSIBLE.

7.3.3. Emergency stop devices

EMERGENCY STOP BUTTON. The machine is fitted with an emergency stop identified by a red button on a
yellow background located on the front right base-frame. The function of this device is to stop all machine
functions immediately and to KEEP them stopped.
To activate the emergency stop:
Press in the emergency stop button from the front. An audible warning is produced and ALM/EMER appears on
the display.
To deactivate the audible warning press the STOP key.
To continue the operation:
Release the emergency stop by making a quarter turn in the direction of the arrow shown on the button itself.
Press the STOP key of the multi-function keyboard or deactivate the audible warning and next the START key
to restart the operation.
The REV key allows the roll to rotate in the opposite direction to the linen input direction. Use only under
exceptional conditions.