System Tools Mode; Configuration Menu. Introduction And Access - GIRBAU PB32 Series Installation, Operation And Maintenance Instructions Manual

Flatwork ironer
Table of Contents

Advertisement

7.7. System tools mode

Group of tools destined to preparing, personalizing, informing and controlling the global operation of the ironer.
Within this group of tools, there are two large groups or intervention areas:
System CONFIGURATION.
CONSULTING the ironer characteristics, executed programs and operations and alarms detected by the
ironer control.
TEXT MESSAGES. The user can programme a text message that will appear after a certain operation time,
also programmable.
Managing and using these areas appear on the screen in written text.
Accessing the TOOLS mode menus
The system TOOLS mode menus are accessed from the main menu.
Do not start any ironing program.
Select the icon TOOLS mode and confirm the selection with the OK key.
The distinct menus of the TOOLS mode appear.
Select the desired menu using the ▲ / ▼ keys and press the SEL key.

7.7.1. Configuration menu. Introduction and access

This intervention menu offers the possibility to activate or modify a group of parameters and values, distributed
among different submenus, which condition the ironer's operation.
The submenus are:
 Configuring the parameters for usage and programming
 Setting the clock
 Managing the security codes
Configuring operation and programming parameters
Below, the distinct parameters found in the CONFIGURATION menu are listed.
Shown at each parameter:
 Identification of the parameter: description that appears on the screen.
 Explanation of the parameter.
 Configurable values or range.
 Factory settings: the configuration at works of the ironer will depend on the purchase specifications.
 Configuration by default: is the option programmed by default at the ironer control. The values configured by
default will always appear when a GENERAL INITIALIZATION is executed or when a new control board is
installed onto the ironer.
When the factory settings value and the default configuration value coincide, it is only indicated as the factory
value.
The ▲ / ▼ keys allow the access to different parameters. The MOD key modifies the value of the selected
parameter.
Accessing a new parameter or pressing the  key saves the selection made.