GIRBAU PB32 Series Installation, Operation And Maintenance Instructions Manual page 69

Flatwork ironer
Table of Contents

Advertisement

HEATING CIRCUIT ASSEMBLING (Fig. 5.15).
 Steam connection shown as A
 Condensate connection shown as B
 Safety valve connection C
Characteristics of the connection flange: Type: PN-16.
Before connecting the ironer install A WATER SEPARATOR with ball float drain on the main steam supply line.
In order to guarantee the supply of dry steam, the functioning of this separator must be checked regularly.
The fitting of a pressure gauge after the purge is highly recommended.
Insert a CHECK VALVE into the condensate return.
The manufacturer supplies a set of suitable seals for the connection flanges.
The CO2 and the O2 dissolved in the steam can damage the roll and pipes. Carry out a suitable
chemical treatment on both steam and condensate.
THE DISCHARGE FROM THE SAFETY VALVE SHOULD BE CARRIED OUT IN SUCH A MANNER WHICH
EFFECTLY PREVENTS THE EVACUATED FLUID FROM CAUSING DAMAGE TO PERSONS OR GOODS.
THIS DISCHARGE SHOULD BE DONE FOLLOWING THE CURRENT NORMATIVE OF THE COUNTRY
WHERE MACHINE IS IN USE.
Steps for the connection
Fig. 5.15
69
Code no. 550038
Rev. no. 16/1018

Hide quick links: