6.2.4. CE models with radiant burner. Natural gas and propane gas heating

ETL models with a radiant burner. Propane gas heating
60Hz models with a radiant burner. Natural gas and propane gas heating
Gas supply pressure control (Fig. 6.4)
Before starting the ironing program, remove the cover
from the gas valve protection base-frame.
Insert the pressure pipe through one of the holes drilled in
the base of the base-frame.
Loosen the pressure outlet screw A (without removing it
completely). At this point, connect the pressure gauge
pressure outlet pipe.
The arrow C indicates the direction of the gas flow.
Refit the base-plate cover and start up the machine as
indicated in Section 6.1.
Approximately one minute after connecting the gas flow
solenoid valve, check that the input pressure corresponds
to the value indicated in the tables in Sections 4.3 and
4.4. The gas pressure must remain stable regardless of
possible differences in consumption caused by the
operation of other gas appliances connected to the same
line.
If this is not the case, contact the installing company.
Note that the input pressure differs depending on the type
of gas.
Once the gas pressure control is completed:
 Stop the ironer and turn off the power and gas supply.
 Open the cover, remove the pressure gauge pipe and
tighten the screw A.
 Refit and properly secure the base-frame cover.
WARNING!
BE SURE TO TIGHTEN THE PRESSURE OUTLET SCREW (A/Fig. 6.4).
FAILURE TO DO SO WOULD RESULT IN A GAS LEAK THAT COULD CAUSE A SERIOUS ACCIDENT.
Initial start-up
76
Fig. 6.4