8.3. Stop modes

8.3.1. Normal machine stopping

PRESS
KEY. The heating system is turned off. The ironer enters a cooling situation: the rotation speed is
reduced and the extractor fan is kept running while the roll temperature exceeds 100º C (202º F).
When the temperature falls below this value, the rotation of the roll is halted, the extractor halts and the main
menu icons are displayed on the screen.

8.3.2. General Stop

Disconnecting the mechanically lockable isolator switch, located on the base-frame side cover. COMPLETELY
disconnects the machine from the power supply. Its use is recommended for maintenance interventions and in
situations of prolonged machine stoppage.
Mechanically locking switch breaker
Set the switch breaker at the " 0" position.
Fit a padlock on the opening to prevent the switch breaker being handled by others.
CAUTION!
ONCE THE SWITCH BREAKER HAS BEEN MECHANICALLY LOCKED, OPENING THE BASE-FRAME
SIDE COVER IS NO LONGER POSSIBLE.

8.3.3. Emergency stop devices

EMERGENCY STOP BUTTON. The machine is fitted with an emergency stop identified by a red button on a
yellow background located on the front right base-frame. The function of this device is to stop all machine
functions immediately and to KEEP them stopped.
To activate the emergency stop:
Press in the emergency stop button from the front. An audible warning is produced and ALM/EMER appears on
the display.
To continue the operation:
Release the emergency stop by making a quarter turn in the direction of the arrow shown on the button itself.
Press the
key on the multifunction keyboard to deactivate the sound alarm and then press
operation.
Operating and use. Logi Control