PB/PBP51, X20
MODEL ERROR
PB32, X13
ALM / Err0
Unidentified machine model
Probable cause:
Reading error in model identification bridges.
Lack of coherence between identification bridges and machine model
Fault in the machine's microprocessor
Procedure:
Disconnect the power supply from the machine and reconnect after five minutes.
If fault persists or is frequently repeated, disconnect the power supply and close the manual gas inlet valve
(machines heated with gas).
Contact Authorised Technical Services.

12.2. Expanded information on alarms related to the inverter

On PB/PBP51, X20 ironers, the alarm code is preceded by the description. GENERAL INVERTER FAILURE
ALARM CODE
PB/PBP51, X20
Fault 41, 42, 43
PB32, X13
U-41, 42, 43
Fault 47
PB/PBP51, X20
PB32, X13
U-47
PB/PBP51, X20
Fault 48
PB32, X13
U-48
PB/PBP51, X20
Fault 49
PB32, X13
U-49
PB/PBP51, X20
Fault 50
PB32, X13
U-50
PB/PBP51, X20
Fault 52
U-52
PB32, X13
PB/PBP51, X20
Fault 55
PB32, X13
U-55
PB/PBP51, X20
Fault 56
PB32, X13
U-56
PB/PBP51, X20
Fault 59
PB32, X13
U-59
Fault **
PB/PBP51, X20
PB32, X13
U-**
Alarms
FAULT DESCRIPTION
Inverter output missing phase
Inverter overloaded
Low voltage in inverter D.C. bus
Over voltage in inverter D.C. bus
Short-circuit in motor or on motor connection
Missing phase on inverter supply or too high voltage imbalance
Inverter overheated
Discharge from inverter output phase to ground
Overcurrent inverter
Unidentified inverter failure