8.4.2. Making specific operating changes as a program is running

By pressing the keys on the control panel, the user can modify the values of the program parameters. The new
settings will remain in memory until the program ends.
Parameters that can be selected:
Roll speed
Programmed ironing temperature
Automatic roll speed control
Stopping and reversing the heating system
Press the buttons indicated to view and/or modify operating options.
The LED associated with the key indicates the selected parameter.
Roll speed
View the programmed roll speed.
M
: Roll speed in metres/minute
Ft
: Roll speed in feet/minute
When viewing the speed, the
speed of the roll.
Programmable ranges:
LS models
M: 1.0 – 5.0 m/min
Ft:
When operating with automatic speed control (AUT selection), this option displays the REAL
operating speed but does not allow it to be changed.
Programmed ironing temperature
C : temperature in degrees Celsius
F : temperature in degrees Fahrenheit
When viewing the temperature, the
to the programmed temperature of the roll.
Programmable ranges:
C : 70 – 170 ºC.
F : 160 – 340 ºF.
Automatic roll speed control
When automatic roll speed control is activated, the system automatically adjusts for optimum
drying of the linen.
Press the
When the LED is lit, the automatic control is activated.
Stopping the heating system
Pressing this key deactivates the heating system.
The LED corresponding to the Start Heating System key remains unlit.
Starting the heating system
Pressing this key activates the heating system.
The heating system will then turn on according to the programmed temperature.
Start key LED indication
LED on ..................... :
LED flashing ............. :
LED off ..................... :
Operating and use. Logi Control
HS models
M: 1.0 – 11.0 m/min
4 – 41ft/min
Ft:
key to activate or deactivate this function.
heating system activated and operating.
the heating system is activated but temporarily stopped because the
programmed temperature has yet to be reached.
heating system deactivated.
keys can be used to make particular changes to the
4 – 52 ft/min
keys can be used to make particular changes
112
Code no. 550038
Rev. no. 16/1018