Goose Function Block To Receive A Double Point Goosedprcv; Function Block; Functionality; Operation Principle - ABB RELION 630 Series Technical Manual

Power management
Hide thumbs Also See for RELION 630 Series:
Table of Contents

Advertisement

Section 3
Basic functions
3.23
3.23.1
3.23.2
3.23.3
3.23.4
126
GOOSE function block to receive a double point
GOOSEDPRCV

Function block

GOOSEDPRCV
BLOCK
^DPOUT
DATAVALID
COMMVALID
TEST
IEC10000249-1-en.vsd
IEC10000249 V1 EN
Figure 65:
Function block

Functionality

GOOSEDPRCV is used to receive a double point value using IEC61850 protocol via
GOOSE.

Operation principle

The DATAVALID output is HIGH if the incoming message is with valid data.
The COMMVALID output becomes LOW when the sending IED is under total failure
condition and the GOOSE transmission from the sending IED does not happen.
The TEST output will go HIGH if the sending IED is in test mode.
The input of this GOOSE block must be linked in Signal Matrix by
means of a cross to receive the double point values.
The implementation for IEC 61850 quality data handling is restricted
to a simple level. If quality data validity is GOOD, the DATAVALID
output is HIGH. If quality data validity is INVALID,
QUESTIONABLE, OVERFLOW, FAILURE or OLD DATA, the
DATAVALID output is LOW.