Goodrive300-21 integrated machine for air compressor
Fault
Fault type
code
Phase loss on input
SPI
Phase loss on output
SPO
Rectifier module
OH1
overheating
Inverter module
OH2
overheat
EF
External fault
CE
communication fault
Current detection
ItE
Motor autotuning
tE
restarted;
The voltage of the grid is too
low;
Load is too large.
Phase
fluctuation occurred on input
side
R, S, T.
Phase loss occurred to U, V, W
output (or the three phases of
side
motor is asymmetrical).
Air duct is blocked or fan is
damaged;
Ambient temperature is too
high;
Long-time overload running.
S external faulty input terminal
action.
Baud rate is set improperly;
Communication line fault;
RS485
Incorrect
address;
Communication suffers from
strong interference.
Poor contact of the connector
of control board;
Hall component is damaged;
fault
Exception
amplification circuit.
The motor capacity does not
match the inverter capacity;
Motor
improperly;
fault
The parameters gained from
autotuning
from the standard parameters;
Autotuning timeout.
Possible cause
loss
or
violent
communication
occurred
parameter
is
deviate
sharply
-
-
71
Solution
Check the grid voltage;
Select the inverter with larger
power;
Select a proper motor.
Check the input power;
Check the installation wiring.
Check the output wiring;
Check the motor and cables.
Ventilate the air duct or replace
the fan;
Lower the ambient temperature.
Check external device input.
Set proper baud rate;
Check
the
communication interfaces;
Set the communication address
correctly;
Replace or change the wiring to
enhance the anti-interference
capacity.
Check
the
connector
re-plug;
Replace the hall component;
to
Replace the main control board.
Change the inverter model;
Set proper motor type and
nameplate parameters;
set
Empty the motor load and carry
out autotuning again;
Check the motor wiring and
parameter setup;
Check whether the upper limit
frequency is larger than 2/3 of
the rated frequency.
Troubleshooting
wiring
of
and
Need help?