Goodrive300-21 integrated machine for air compressor
Function
Address
BIT0:=1 Clear the working time of part 1
=0 invalid
BIT1:=1 Clear the working time of part 2
=0 invalid
BIT2:=1 Clear the working time of part 3
=0 invalid
BIT3:=1 Clear the working time of part 4
200FH
=0 invalid
BIT4:=1 Clear the working time of part 5
=0 invalid
BIT5:=1 Clear the working time of the device
=0 invalid
BIT6:=1 Solenoid valve loading
=0 Solenoid valve unloading
Maintenance set time of part 1,
2010H
range: 0–65535
Maintenance set time of part 2,
2011H
range: 0–65535
Maintenance set time of part 3,
2012H
range: 0–65535
Maintenance set time of part 4,
2013H
range: 0–65535
Maintenance set time of part 5,
2014H
range: 0–65535
2015H
Working time of part 1; 0–65535
2016H
Working time of part 2; 0–65535
2017H
Working time of part 3; 0–65535
2018H
Working time of part 4; 0–65535
2019H
Working time of part 5; 0–65535
201AH
Running time of the device; 0–65535
Command reference during fan debugging
mode
0: No action
1: Run
201BH
2: Jogging
3: Stop
4: Coast to stop
5: Reset faults
-
103
Data description
-
Communication protocol
R/W
R/W
W
W
W
W
W
W
W
W
W
W
W
R/W
Need help?
Do you have a question about the Goodrive300-21 Series and is the answer not in the manual?