INVT Goodrive300-21 Series Operation Manual page 70

Dual-inverter integrated machine for air compressor
Hide thumbs Also See for Goodrive300-21 Series:
Table of Contents

Advertisement

Goodrive300-21 integrated machine for air compressor
Control long-term vibration: If the cycle of periodic vibration is longer than the set value of integral
time (Ti), it indicates the integral action is too strong, prolong the integral time (Ti) to control vibration.
Control short-term vibration: If the vibration cycle is as short almost the same as the set value of
differential time (Td), it indicates the differential action is too strong. Shorten the differential time (Td)
to control vibration. When the differential time (Td) is set to 0.00 (namely no differential control), and
there is no way to control vibration, decrease the proportional gain.
Related parameter list:
Function
code
PID reference
P09.00
PID reference
preset through
P09.01
Response
Response
Name
0: Keypad (P09.01)
1: Analog P1-reference
2: Reserved
3: Analog P2-setting
4: Reserved
source
5: Reserved
6: Modbus communication
7–9: Reserved
10: Pressure setting for air compressor-specific
function
-100.0%–100.0%
keypad
Before adjustment
After adjustment
Time t
After adjustment
Before adjustment
Time t
Description
-
-
66
Function description
Default
0
0.0%