Goodrive300-21 integrated machine for air compressor
Function
code
P17.07
Exciting current
P17.08
Motor power
P17.09
Output torque
Estimated motor
P17.10
frequency
P17.11
DC bus voltage
Digital input terminal
P17.12
Digital output
P17.13
terminal status
P17.16
Master fault code 0–45 (See P07.27–P07.32 for details)
P17.17
Fan fault code
P17.19
P1–input voltage
P17.20
PT1 input voltage
P17.21
P2–input voltage
Name
-3000.0–3000.0A
-300.0% –300.0% (of the motor rated power)
-250.0–250.0%
0.00–P00.03
0.0–2000.0V
0000–00FF
status
0000–000F
0–38 (See P07.27–P07.32 for details)
Displays analog input voltage value of
P1-channel. 2.00V–10.00V corresponds to 4–
50mA. P05.32-P05.34 corresponds to
pressure 0.0-P18.04. When P1-input voltage
is detected to be above 9.8V or below 1V, it is
deemed as pressure signal fault.
Range: 0.00–10.00V
Displays the analog input voltage value of PT1
channel. Connect PT100 thermal resistor
temperature sensor in air compressor mode,
and different resistance value will be
generated under different temperature
Different resistance value corresponds to
different input voltage. Therefore, the input
voltage value can correspond to the
corresponding detection temperature. The
input voltage P18.28-P18.29 corresponds to
-20° C-150° C.
Range: 0.00–10.00V
Displays analog input voltage value of
P2-channel. 2.00V–10.00V corresponds to 4–
50mA. P05.42-P05.44 corresponds to
pressure 0.0-P18.38. When P2-input voltage
is detected to be above 9.8V or below 1V, it is
deemed as pressure signal fault.
Range: 0.00–10.00V
Description
-
-
47
Function description
Default Modify
●
0.0A
●
0.0%
●
0.0%
●
0.00Hz
●
0V
●
0
●
0
●
0
●
0
●
0.00V
●
0.00V
●
0.00V
Need help?
Do you have a question about the Goodrive300-21 Series and is the answer not in the manual?