INVT Goodrive300-21 Series Operation Manual page 60

Dual-inverter integrated machine for air compressor
Hide thumbs Also See for Goodrive300-21 Series:
Table of Contents

Advertisement

Goodrive300-21 integrated machine for air compressor
Function
code
Time-out time of
P18.45
maintenance
Maintenance set
P19.00
time of part 1
Maintenance set
P19.01
time of part 2
Maintenance set
P19.02
time of part 3
Maintenance set
P19.03
time of part 4
Maintenance set
P19.04
time of part 5
Working hours of
P19.05
P19.06
Runtime of part 2
P19.07
Runtime of part 3
Working hours of
P19.08
P19.09
Runtime of part 5
Actual output power
P19.10
of motor
P19.11
Current pressure
Name
ensure the running current of the master will
not exceed automatic frequency reduction
threshold.
0–8000h
When this parameter is set to "0", the
maintenance time-out function is invalid. If it is
set to non-zero value, then the system will
release maintenance time-out pre-alarm by
changing BIT11 of P19.14 to 1 in cases where
the working time, after part maintenance
pre-alarm, exceeds the value set by P18.45.
P19.00–P19.04 displays the set value of
maintenance time on five kinds of parts.
When the accumulated working time of the
part exceeds the corresponding set value,
the system will release pre-alarm by
changing the BIT of P19.14 to 1. If set to "0",
working time pre-alarm of the parts will be
invalid.
P19.05–P19.09 displays the working hours of
part 1
corresponding parts.
Range: 0–65535h
part 4
It displays the output frequency of the motor
and can be calibrated by setting P18.22.
Range: 0.0–6553.5kW
Displays the exhaust pressure value detected
currently.
Description
-
-
56
Function description
Default Modify
0
0
0
0
0
0
0
0
0
0
0
0.0kW
0.00Mpa