Point Thermography; Line Thermography; Area Thermography; Set Shielded Region - HIKVISION DS-2TD2636-15 User Manual

Thermal & optical bi-spectrum network camera
Table of Contents

Advertisement

Thermal & Optical Bi-spectrum Network Camera User Manual
5. You can shield certain area from being detected. Refer to Set Shielded Region for detailed
settings.
6. Click Save.
Click Live View, and select thermal channel to view the temperature and rules information on
live view.

3.3.5 Point Thermography

Configure the temperature measurement rule and click any point in live view to monitor the
temperature.
Steps
1. Click in the live view and a cross cursor showed on the interface.
2. Drag the cross cursor to desired position.
Go to Live View interface to view the temperature and rule of the point in thermal channel.

3.3.6 Line Thermography

Configure the temperature measurement rule and monitor the maximum temperature of the line.
Steps
1. Click and drag the mouse to draw a line in the live view interface.
2. Click and move the line to adjust the position.
3. Click and drag the ends of the line to adjust the length.
Go to Live View interface to view the maximum temperature and rule of the line in thermal
channel.

3.3.7 Area Thermography

Configure the temperature measurement rule and monitor the maximum temperature of the
area.
Steps
1. Click and drag the mouse in the liveview to draw the area and right click to finish drawing.
2. Click and move the area to adjust the position.
3. Drag the corners of the area to adjust the size and shape.
Go to Live View interface to view the maximum temperature and rule of the area in thermal
channel.

3.3.8 Set Shielded Region

You can configure areas from being detected.
Steps
1. Check Enable Shield Area.
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents