106

Reset switches

There are four reset switches, two are allocated to the master controllers and the other
two to the routers. These switches are only to be used if a fault is suspected; see "To
reset a master controller or router" on page 268. Do not operate these switches
during normal operation, they are for fault correction purposes only.
1
2
3
4

Comms

The comms section of the output bay deals with communications, or talk, and
comprises: a signal generator section (containing a sinusoidal oscillator and pink
noise generator); a talk mic section for control of a control surface-located talkback
microphone; and a talk/osc routing section for sending signal generator signals and
talk mic signals to buses within the console. The controls in this area are not affected
by automation.
1
mc -1 set switch for resetting master couturier
1.
2
r - x set switch for resetting the X router.
3
mc -2 set switch for resetting master couturier
2.
Chapter 6: Output Bay