18-input digital mixer for ipad/android tablets with 16 midas pro preamps, integrated wifi module and multi-channel usb audio interface, 12-input digital mixer for ipad/android tablets with 4 midas pro preamps, 8 line inputs, integrated wifi module and us (48 pages)
IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
Midas EC-Declaration of Conformity The undersigned, representing the following manufacturer Manufacturer: Address: Midas Klark Teknik Ltd. Klark Industrial Park, Walter Nash Road, Kidderminster. Worcestershire. DY11 7HJ. hereby declares that the following product Product Type Number Product Description Nominal Voltage(s) Current Freq.
Licences The following are the license agreements applicable to the Midas Digital Equipment. End-User Licence Agreement for Midas™ and Klark Teknik™ Software IMPORTANT - Please read this document carefully before using this Midas™ or Klark Teknik™ Product. This is an agreement governing your use of software or other machine instructions already installed on this Midas™...
Page 8
DATE INFORMATION. You understand that the Company may update or revise the Software but in so doing incurs no obligation to furnish such updates to you. However, the Company may in its discretion make updates available from time to time upon such terms and conditions as it shall determine.
Page 9
and the Courts of England and Wales will have exclusive jurisdiction to hear and decide any dispute concerning it or its formation. No breach by you of any provision of this Licence shall be waived or discharged except with the express written consent of the Company and no failure or delay by the Company to exercise any of its rights under this Licence shall operate as a waiver thereof and no single or partial exercise of any such right shall prevent any other or further exercise of that or any other right.
Precautions Before installing, setting up or operating this equipment, make sure that you have read and fully understand all of this section and the “IMPORTANT SAFETY INSTRUCTIONS” at the front of this manual. This equipment is supplied by a mains voltage that can cause electric shock injury! The following must be observed in order to maintain safety and electromagnetic compatibility (EMC) performance.
Precautions • Power plug must be inserted in a socket communications. Operation of this equipment outlet provided with a protective earth in a residential area is likely to cause harmful contact. The electrical supply at the socket interference in which case the user will be outlet must provide appropriate required to correct the interference at his own over-current protection.
Chapter 1: Introduction The DL471 DSP is a one-unit (1U) high 19” rack unit that forms part of the modular digital signal processor (DSP) engine. It features its own discrete power supply, AES50 and Ethernet interfaces, as well as a dual, ultra high-speed, contra-rotating data loop for direct processor-to-processor communications.
Chapter 1: Introduction About this manual This is the operation manual for the DL471 DSP. It is intended to help get your DL471 DSP installed and in operation as quickly as possible by giving you unpacking, installation, connection, setting up and operation instructions. To help familiarise yourself with the DL471 DSP there is a description of the front and rear panels, along with easy-to-follow user instructions.
Chapter 2: Front Panel The front panel comprises various sections, as follows: Item Description Ethernet control monitoring panel; see page 4. Cobranet audio monitoring panel; see page 4. AES50 audio monitoring panel; see page 4. link sync monitoring panel; see page 4. Control panel (see “Control panel”...
Chapter 2: Front Panel Ethernet control panel The Ethernet control panel has two green LEDs, X and Y, which illuminate to indicate link status, as follows: • LED illuminated = good • LED extinguished = bad • LED flashing = data activity. Cobranet audio panel The Cobranet audio panel has two green LEDs, X and Y, which illuminate to indicate Cobranet traffic.
Chapter 3: Rear Panel The rear panel comprises the following: • X and Y AES50 audio digital EtherCon® XLR sockets. • Two 25-way link sockets for linking the DSP units together. • X and Y Ethernet control digital EtherCon® XLR sockets. •...
Chapter 3: Rear Panel Indicators Link status: green = good; = bad. link 0 Data: green = good; = error. Link status: green = good; = bad. link 1 Data: green = good; = error. Pulsating green = good active link. Illuminated green = good back-up link.
Chapter 4: Getting Started This chapter shows you how to connect up, switch on, set up and configure the DL471 DSP unit. Connecting up Connect up the following to the rear panel of your DL471 DSP unit: • AES50: connect the cables from the AES50 audio sockets (bank 0 or bank 1) from the X and Y routers to the appropriate AES50 audio X and Y sockets on the unit.
Page 24
Chapter 4: Getting Started DL471 DSP Operator Manual...
Chapter 5: Programming Mode This chapter describes the programming mode, which lets you set up your DL471 DSP. About the programming mode In programming mode the four programming buttons in the control panel navigate and select options from four menus. These menus (see “Menus” on page 13) are used for setting up the unit ID, checking the internal temperature of the unit and changing the brightness and contrast of the LCD screen and LEDs, and changing the contrast of the LCD screen.
Chapter 5: Programming Mode Menu flowchart (menus 1 to 4) Default display Menu 1 Menu 2 In this example, the “bright” LED brightness option has been selected Menu 3 Pressing MENU takes you to the default screen, which now has the new brightness setting Menu 4 Go to display...
Page 27
Menu flowchart (menus 1 to 4) In this example, ID number “15” has been selected Select from ID range 0 to 255. Pressing MENU takes you to the default display, which now shows the new unit ID number In this example, the “min” (minimum) LCD contrast option has been selected Pressing MENU takes you...
Chapter 5: Programming Mode Menu flowchart (menus 5 to 8) Menu 5 Menu 6 Menu 7 Menu 8 In this example, the “133MHz” AME link speed option has been selected Pressing MENU takes you to the default screen DL471 DSP Operator Manual...
Menus Menus The eight menus in programming mode are as follows: • Unit ID (1) — for setting up the DL471 DSP’s network unit ID (see “Unit ID menu (1)” below). • Temperature (2) — for viewing the temperature within the DL471 DSP unit. The temperature value continually updates so that you can view the temperature fluctuations (in 0.25°C increments).
Chapter 5: Programming Mode LED brightness menu (3) The “LED brightness” menu allows you to alter the brightness — “bright”, “medium” or “dim” — of the LEDs in the panels to the left of the LCD screen and also of the LCD screen itself.
Menus Press SELECT to select the currently displayed contrast. The flashing will stop. Press MENU. The contrast of the LCD screen will now be at the newly configured level. AMELink Speed menu (8) The “AMELink Speed” menu lets you choose the speed of the AME link, which can be 125MHz or 133MHz.
Chapter 6: Operation This chapter gives details on the operation of the DL471 DSP. Start-up sequence After switching on the unit (see “Switching the unit on/off” on page 7), it runs through a start-up sequence as shown on the LCD screen (right), which ends with the default display. The “waiting for client”...
Chapter 6: Operation Error messages During operation the following messages will appear on the second line of the LCD screen display to inform you of a communication problem between the unit and the control centre’s master controller. When either message is displayed, the unit’s outputs are muted and the unit has no functionality.
Appendix A: Technical Specification This appendix contains the technical specifications specific to the DL471 DSP. For system related XL8 Control Centre specifications and for full technical specifications for the XL8 Live Performance System, please refer to its Owner’s Manual (part number DOC02-XL8).
Appendix B: Service Information This appendix gives you servicing information for your unit. If you are in any doubt or have queries about any of the procedures in this appendix, contact Midas Technical Support. Contact details can be found at the front of this manual.
Appendix B: Service Information Equipment disposal When this equipment has come to the end of it useful life, its disposal may come under the DIRECTIVE 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equipment (WEEE). Hazardous substances in WEEE contaminate water, soil and air and ultimately put at risk our environment and health.
Appendix C: XL8 Live Performance System The XL8 Live Performance System is a very powerful and flexible audio processing system that provides a complete solution for any audio mixing and signal distribution application in a live sound environment. The standard XL8 system offers 96 channel inputs, 51 outputs, 51 buses (32 auxes/groups, 16 matrices and three masters), 16 on-board effects processors, PEQs (four-band on inputs and six-band on outputs), up to 48 assignable GEQs (if all stereo effects units are being used), 16 configurable stereo effects (from eight options),...
Page 40
Appendix C: XL8 Live Performance System Configuration • All outputs have six-band parametric EQ and five-mode compressor styles. • Up to 16 stereo FX units. • Up to 48 assignable GEQs (16 if all 16 stereo FX units are being used). •...
Page 41
Features User interface - status visibility • Daylight-visible screens. • Metering. • 63 discrete 20-segment LED meters. • Discrete metering for dynamics and direct outputs. • “All the meters all of the time”. • “ST” assign switch. • Eight channels of key data plus single channel strip per input screen. Dual operators - perfect for festival situations •...
Appendix C: XL8 Live Performance System System components (standard supply) The standard XL8 Live Performance System comprises the following equipment: • XL8 Control Centre (1-off): Comprises five discrete, independent bays, each with its own power supply, surface modules, surface processor, GUI processor and GUI screen.
System interconnections System interconnections Figure 1 shows basic system interconnectivity and indicates where the XL8 Control Centre (highlighted in red) sits within the system. This figure also illustrates redundancy by showing that the two halves of the system - left and right - are identical (ignoring the DN9331 RAPIDE).
Appendix C: XL8 Live Performance System FOH and MON The XL8 Live Performance System can be used as a front of house (FOH) or stage monitor (MON) system. Also, by sharing the four mic splitters, these two types of system can be used in tandem, as shown in Figure 2 on page 28. Figure 4 on page 35 shows in more detail the interconnections between each unit in a typical XL8 Live Performance System FOH and MON set up.
Mix matrix Mix matrix Ultimately, the mix matrix defines the XL8 Control Centre’s capability. Probably the best way to imagine the mix matrix is to think of an analogue console layout, where inputs run vertically and buses run horizontally. A mix matrix is usually defined as the number of buses and the quantity of simultaneously-mixable inputs there are per bus.
Appendix C: XL8 Live Performance System Each of the 16 auxiliary inputs has: • Input gain. • Source from internal FX or external pool input. • Fader. • Panpot (SIS™). • Routing via level controls to the 16 matrix buses. •...
Appendix C: XL8 Live Performance System Uses of the configurable audio connections The standard XL8 Live Performance System has a total configurable audio channel count (on the DL451 I/O units) of between 120 and 240, depending on the mix of analogue and digital I/O (excluding the non-configurable 96 mic inputs on the DL431 mic splitter).
Surround capabilities The maximum count of any one type of connection is: • 96-off input insert sends. • 96-off input insert returns. • 96-off input compressor external side chain connections. • 96-off input noise gate external side chain connections. • 96-off input direct outputs. •...
Appendix C: XL8 Live Performance System All system connections are duplicated for full dual redundancy. Resilience to failure (redundancy) The XL8 Live Performance System is tolerant of any single failure of hardware or software. To achieve this the system employs dual-redundancy, where a key component has an identical redundant spare that is ready to take over should it fail.
Page 51
Resilience to failure (redundancy) Local I/O units Internal bay processor Dual redundant XL8 Control Centre internal master controller Dual redundant internal router Control data Cat6/optical ‘snake’ Audio data N + 1 redundant Control and spare audio data Router Clock sync Monitor This diagram gives a more detailed...
Page 52
Appendix C: XL8 Live Performance System Local I/O units XL8 Control Centre Not active Internal bay processor Internal master controller Internal router units I/O units Router This diagram illustrates an extreme Monitor example of dual redundancy in a standard FOH and stage monitor set up, splitters where one half of the...
Page 53
Resilience to failure (redundancy) Local I/O units Not active Internal bay processor Internal master controller XL8 Control Centre Internal router units I/O units Router Router (healthy) (faulty) Monitor This diagram illustrates the effects of a single router splitters failure in an FOH and (shared) stage monitor set up.
Appendix C: XL8 Live Performance System Control software The XL8’s operating system is Linux, which is an open-source, stable, proven operating system (OS). Linux is used in many mission-critical applications worldwide and has allowed Midas’ software engineers to write a ground-up system that contains no ‘hidden’...
Page 55
Integration of third party software The XL8 Control Centre features a four-way KVM switch on the output module screen, as well as external video IN and OUT for each of the five screens. Control centre views can be routed to external monitors, and external video sources can be displayed on the control centre’s screens.
Page 56
Appendix C: XL8 Live Performance System DL471 DSP Operator Manual...
Appendix D: Setting Up An XL8 System This chapter shows you how to set up an XL8 Live Performance System to its default configuration. Note: If you want to set up the XL8 Live Performance System using a configuration other than the default, please contact Midas Technical Support for details. Initial set-up procedure Initial system set-up basically comprises: •...
Appendix D: Setting Up An XL8 System Outboard equipment racks To ensure the correct installation and function of the outboard equipment, such as the DL4n1 units and DN9696 recorder, the racks must meet the following general requirements. • Shock mounting (for non-installation environments): The racks must provide adequate shock protection of the units they house by incorporating appropriately- designed shock protection methods, for example, a foam-suspended rack or a frame suspended on anti-vibration mounts etc.
Wiring instructions Stage rack 2 Stage rack 2, also known as the “DL461/DL471 engine rack”, contains the two routers and 10 DSP units. Important: In general, the physical location of the hardware units within each rack is not critical, and alternative configurations are acceptable for different packaging preferences.
Page 60
Appendix D: Setting Up An XL8 System >> To connect the routers to the Stage rack 3 units • Mic splitters: In AES50 audio - bank 1 on the X router, connect sockets 3 and 4 to the AES50 audio - A X sockets on the mic splitters. Repeat for the Y router, using the mic splitters’...
Appendix D: Setting Up An XL8 System XL8 system interconnections This diagram shows the network interconnections for a typical FOH XL8 system. Rear of FOH XL8 Control Centre RAPIDE Connect to both X and Y networks Note: All connections are dual redundant, so the system can operate quite normally using either the X or Y cables.
Page 63
XL8 system interconnections FOH rack Note: For connections specific to the 19” rack units, please refer to their respective operator manuals ID: 1 Config: I/O/D IP: 192.168.36.1 ID: 2 Caution! Config: I/O/D Don’t forget the IP: 192.168.36.2 interconnection between the two routers, as system snake redundancy will be compromised without it.
Appendix D: Setting Up An XL8 System Cable type and function The following table shows the type, terminations and function of the XL8 system’s interconnecting cables. Please read the table in conjunction with the network interconnections diagram on page 46. Cable From Description...
Powering the XL8 system Powering the XL8 system The following details the recommended power up and power down procedures for the XL8 system. >> To power up the XL8 system Important Note: DO NOT switch on the speaker sub-system until after the start-up of the XL8 system has been completed.
Appendix D: Setting Up An XL8 System Switching the XL8 Control Centre on/off Carry out the following to switch the XL8 Control Centre on/off in a safe manner, observing all WARNINGS and Cautions. >> To switch on the XL8 Control Centre WARNING! DO NOT INSERT OR REMOVE A POWERCON®...
Setting up the ID of the DL4n1 units >> To switch off the XL8 Control Centre Make sure you have saved any shows, scenes or settings you require (see “Saving your show files to a USB memory stick” on page 56). At the GUI, choose home Preferences Shutdown System.
Page 68
Appendix D: Setting Up An XL8 System DL471 DSP Operator Manual...
Page 69
Thank you for reading through this Operator Manual. We hope you found it useful. Please feel free to send us your comments. More detailed information on the XL8 can be found in the XL8 Live Performance System Owner’s Manual (part number DOC02-XL8). This is available for download from our website.
Page 70
Midas Klark Teknik Limited Klark Industrial Park, Walter Nash Road, Kidderminster. Worcestershire. DY11 7HJ. England. Tel: +44 1562 741515, Fax: +44 1562 745371 Email: info@midasklarkteknik.com Website: www.midasconsoles.com...
Need help?
Do you have a question about the XL8 DL471 and is the answer not in the manual?
Questions and answers