18-input digital mixer for ipad/android tablets with 16 midas pro preamps, integrated wifi module and multi-channel usb audio interface, 12-input digital mixer for ipad/android tablets with 4 midas pro preamps, 8 line inputs, integrated wifi module and us (48 pages)
IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
Midas EC-Declaration of Conformity The undersigned, representing the following manufacturer Manufacturer: Address: Midas Klark Teknik Ltd. Klark Industrial Park, Walter Nash Road, Kidderminster. Worcestershire. DY11 7HJ. hereby declares that the following product Product Type Number Product Description Nominal Voltage(s) Current Freq.
Licences The following are the license agreements applicable to the Midas Digital Equipment. End-User Licence Agreement for Midas™ and Klark Teknik™ Software IMPORTANT - Please read this document carefully before using this Midas™ or Klark Teknik™ Product. This is an agreement governing your use of software or other machine instructions already installed on this Midas™...
Page 8
DATE INFORMATION. You understand that the Company may update or revise the Software but in so doing incurs no obligation to furnish such updates to you. However, the Company may in its discretion make updates available from time to time upon such terms and conditions as it shall determine.
Page 9
and the Courts of England and Wales will have exclusive jurisdiction to hear and decide any dispute concerning it or its formation. No breach by you of any provision of this Licence shall be waived or discharged except with the express written consent of the Company and no failure or delay by the Company to exercise any of its rights under this Licence shall operate as a waiver thereof and no single or partial exercise of any such right shall prevent any other or further exercise of that or any other right.
Precautions Before installing, setting up or operating this equipment, make sure that you have read and fully understand all of this section and the “IMPORTANT SAFETY INSTRUCTIONS” at the front of this manual. This equipment is supplied by a mains voltage that can cause electric shock injury! The following must be observed in order to maintain safety and electromagnetic compatibility (EMC) performance.
Precautions Installation Audio connections Before installing the equipment: To ensure the correct and reliable operation of the equipment, only high quality balanced, • Make sure the equipment is correctly screened, twisted pair audio cable should be connected to the protective earth conductor used.
xiii Precautions Safety equipment Special accessories Never remove, for example, covers, housings To comply with part 15 of the FCC Rules, any or any other safety guards. Do not operate special accessories (that is, items that cannot the equipment or any of its parts if safety be readily obtained from multiple retail guards are ineffective or their effectiveness outlets) supplied with this equipment must be...
Page 14
Precautions DL431 Mic Splitter Operator Manual...
Chapter 1: Introduction The DL431 Mic Splitter is a six-unit (6U) high 19” rack unit that provides 24 mic/line inputs. Each input feeds three separate preamps, two of which have separate remote and local gain controls, while the third has fixed gain. The two preamps with gain controls feed separate analogue to digital (A/D) converters, which pass digital audio to the network.
Chapter 1: Introduction • Analogue splits. • Full metering on every channel. • Hi pass 30Hz filter option on every channel. • 48V phantom voltage option on every channel. • Control panel, with LCD screen, for easy unit configuration and channel set up. •...
Chapter 2: Front Panel The front panel comprises the following: Item Description Control panel (see “Control panel” on page 4). AES50 audio panel monitors (see “AES50 audio panel” on page 5). analogue output metering section (see “analogue output metering section” on page 6). isolated C outputs section (see “isolated C outputs section”...
Chapter 2: Front Panel Control panel The control panel has an LCD screen that is used with the three controls underneath (two buttons and a control knob) for controlling the input channel. In programming mode the LCD screen shows the menus, which are navigated and selected using the four programming buttons to the left.
AES50 audio panel AES50 audio panel In the AES50 panel, each X and Y channel — on both the A and B mic amp sections — has a green ok LED and red error LED, which illuminate when communications to these channels is ok or that there is an error, respectively.
Chapter 2: Front Panel analogue output metering section The analogue output metering section has 24 panels each of which monitors a specific analogue output channel. Item Description SELECT switch for selecting the channel; illuminates green to show when channel is selected. 30Hz filter on/off LED indicator;...
Chapter 3: Rear Panel The rear panel comprises the following: • Two banks of 24 output (A and B) XLR connectors (female). • Bank of input XLR connectors (male). • Two sets (for dual redundancy) of mains IEC sockets and on/off switches. •...
LED indicators Item Description Y and X Ethernet control EtherCon® XLRs for connection of ‘tunnelling’ Ethernet. For a description of the LEDs, see “LED indicators” on page 9. USB slave (type B) and host (type A) sockets for connection of a laptop Two mains IEC sockets with on/off switches.
Chapter 4: Getting Started This section shows you how to connect up, switch on, set up and configure the DL431 Mic Splitter. For operating instructions, see Chapter 6 “Operation”. Connecting up Connect up your DL431 Mic Splitter as follows: • Inputs - connect the inputs to the rear of the unit. •...
Chapter 4: Getting Started Setting up Initial setting up of the DL431 Mic Splitter involves allocating an ID for it within the XL8 network system environment (see “To set up the unit’s ID” on page 17). Configuration See Chapter 5 “Programming Mode” for configuration details. DL431 Mic Splitter Operator Manual...
Chapter 5: Programming Mode This chapter describes the programming mode of the DL431 Mic Splitter. In programming mode the four programming buttons in the control panel are used to navigate and select options from a number of menus (see “Menus” on page 16), which let you set up the unit and view information.
Chapter 5: Programming Mode Menu flowchart (menus 1 to 5) Typical default screen Press and hold down for 2 seconds Menu 3 To clear Press and hold for 2 seconds Select from AES50 Status 1 to 6 for A and B Go to page 16 DL431 Mic Splitter...
Page 33
Menu navigation Select from ID numbers 1 to 8 Flashes DL431 Mic Splitter Operator Manual...
Chapter 5: Programming Mode Menu flowchart (menus 6 and 7) Menu 6 Menu 7 Go to page 14 Menus Programming mode has the following menus: • 1 MicSplit ID — for setting up the DL431 Mic Splitter’s network unit ID (see “1 MicSplit ID menu”...
Menus 1 MicSplit ID menu This menu lets you set up the network ID of the DL431 Mic Splitter. There are eight ID numbers available. >> To set up the unit’s ID In programming mode, select menu 1 (see “To select a menu”...
Chapter 5: Programming Mode Press SELECT. 3 Local Mode menu This menu has the following options for setting up the DL431 Mic Splitter for local/console operation: • Local — allows gain and function changes from the unit’s control panel (see “Control panel”...
Menus 4 48V Control This menu lets you set the 48V phantom voltage source. >> To select the 48V phantom voltage source for the unit In programming mode, select menu 4 (see “To select a menu” on page 13). Press the up/down arrow buttons choose the source of the 48V phantom voltage, for example, mic amp B.
Chapter 5: Programming Mode 7 Reset All menu This menu lets you set all of the DL431 Mic Splitter’s settings to default. For example, it will set the ID number to 1, 48V control from A, all gains to 0dB etc. Important: Use this menu with caution.
Chapter 6: Operation This chapter shows you how to operate the DL431 Mic Splitter. Default display The default display appears after the unit has been switched on and has powered up. The following diagram shows a typical default display. Item Description The first line of text displays the company name, model of the unit and the user-configured ID number.
Chapter 6: Operation Adjusting a channel The following instructions show you how to adjust a channel on the DL431 Mic Splitter, and are in the recommended order of operation, as follows: • Select mic amp (A or B). • Select a channel. •...
Appendix A: Application Notes Using the 30Hz filter The DL431 Mic Splitter’s 30Hz filter is an analogue high pass filter (HPF). It is a very low frequency signal filter with a 30Hz corner frequency and 12dB per octave Butterworth roll off. This filter can be switched into circuit following the mic amp to make better use of the analogue-to-digital (A/D) conversion headroom by removing the very low frequency audio content.
Appendix C: Technical Specification This appendix contains the technical specifications specific to the DL431 Mic Splitter. For full technical specifications for the XL8 Live Performance System, see the owner’s manual (part number DOC02-XL8). Due to a policy of continual improvement, Midas reserves the right to alter the function or specification at any time without notice.
Appendix C: Technical Specification Analogue outputs Connector A 3-pin XLR balanced Connector B Independent second channel identical to above Connector C Independent third channel on front-mounted 3-pin XLR, balanced and transformer isolated (with fixed gain of -6dB) Headphone connector 1/4” jack Audio monitor 3-pin XLR balanced Digital (system) outputs...
Appendix D: Service Information This appendix gives you servicing information for your unit. If you are in any doubt or have queries about any of the procedures in this appendix, contact Midas Technical Support. Contact details can be found at the front of this manual.
Appendix D: Service Information Equipment disposal When this equipment has come to the end of it useful life, its disposal may come under the DIRECTIVE 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equipment (WEEE). Hazardous substances in WEEE contaminate water, soil and air and ultimately put at risk our environment and health.
Appendix E: XL8 Live Performance System The XL8 Live Performance System is a very powerful and flexible audio processing system that provides a complete solution for any audio mixing and signal distribution application in a live sound environment. The standard XL8 system offers 96 channel inputs, 51 outputs, 51 buses (32 auxes/groups, 16 matrices and three masters), 16 on-board effects processors, PEQs (four-band on inputs and six-band on outputs), up to 48 assignable GEQs (if all stereo effects units are being used), 16 configurable stereo effects (from eight options),...
Page 50
Appendix E: XL8 Live Performance System Configuration • All outputs have six-band parametric EQ and five-mode compressor styles. • Up to 16 stereo FX units. • Up to 48 assignable GEQs (16 if all 16 stereo FX units are being used). •...
Page 51
Features User interface - status visibility • Daylight-visible screens. • Metering. • 63 discrete 20-segment LED meters. • Discrete metering for dynamics and direct outputs. • “All the meters all of the time”. • “ST” assign switch. • Eight channels of key data plus single channel strip per input screen. Dual operators - perfect for festival situations •...
Appendix E: XL8 Live Performance System System components (standard supply) The standard XL8 Live Performance System comprises the following equipment: • XL8 Control Centre (1-off): Comprises five discrete, independent bays, each with its own power supply, surface modules, surface processor, GUI processor and GUI screen.
System interconnections System interconnections Figure 1 shows basic system interconnectivity and indicates where the XL8 Control Centre (highlighted in red) sits within the system. This figure also illustrates redundancy by showing that the two halves of the system - left and right - are identical (ignoring the DN9331 RAPIDE).
Appendix E: XL8 Live Performance System FOH and MON The XL8 Live Performance System can be used as a front of house (FOH) or stage monitor (MON) system. Also, by sharing the four mic splitters, these two types of system can be used in tandem, as shown in Figure 2 on page 36. Figure 4 on page 43 shows in more detail the interconnections between each unit in a typical XL8 Live Performance System FOH and MON set up.
Mix matrix Mix matrix Ultimately, the mix matrix defines the XL8 Control Centre’s capability. Probably the best way to imagine the mix matrix is to think of an analogue console layout, where inputs run vertically and buses run horizontally. A mix matrix is usually defined as the number of buses and the quantity of simultaneously-mixable inputs there are per bus.
Appendix E: XL8 Live Performance System Each of the 16 auxiliary inputs has: • Input gain. • Source from internal FX or external pool input. • Fader. • Panpot (SIS™). • Routing via level controls to the 16 matrix buses. •...
Appendix E: XL8 Live Performance System Uses of the configurable audio connections The standard XL8 Live Performance System has a total configurable audio channel count (on the DL451 I/O units) of between 120 and 240, depending on the mix of analogue and digital I/O (excluding the non-configurable 96 mic inputs on the DL431 mic splitter).
Surround capabilities The maximum count of any one type of connection is: • 96-off input insert sends. • 96-off input insert returns. • 96-off input compressor external side chain connections. • 96-off input noise gate external side chain connections. • 96-off input direct outputs. •...
Appendix E: XL8 Live Performance System All system connections are duplicated for full dual redundancy. Resilience to failure (redundancy) The XL8 Live Performance System is tolerant of any single failure of hardware or software. To achieve this the system employs dual-redundancy, where a key component has an identical redundant spare that is ready to take over should it fail.
Page 61
Resilience to failure (redundancy) Local I/O units Internal bay processor Dual redundant XL8 Control Centre internal master controller Dual redundant internal router Control data Cat6/optical ‘snake’ Audio data N + 1 redundant Control and spare audio data Router Clock sync Monitor This diagram gives a more detailed...
Page 62
Appendix E: XL8 Live Performance System Local I/O units XL8 Control Centre Not active Internal bay processor Internal master controller Internal router units I/O units Router This diagram illustrates an extreme Monitor example of dual redundancy in a standard FOH and stage monitor set up, splitters where one half of the...
Page 63
Resilience to failure (redundancy) Local I/O units Not active Internal bay processor Internal master controller XL8 Control Centre Internal router units I/O units Router Router (healthy) (faulty) Monitor This diagram illustrates the effects of a single router splitters failure in an FOH and (shared) stage monitor set up.
Appendix E: XL8 Live Performance System Control software The XL8’s operating system is Linux, which is an open-source, stable, proven operating system (OS). Linux is used in many mission-critical applications worldwide and has allowed Midas’ software engineers to write a ground-up system that contains no ‘hidden’...
Page 65
Integration of third party software The XL8 Control Centre features a four-way KVM switch on the output module screen, as well as external video IN and OUT for each of the five screens. Control centre views can be routed to external monitors, and external video sources can be displayed on the control centre’s screens.
Page 66
Appendix E: XL8 Live Performance System DL431 Mic Splitter Operator Manual...
Appendix F: Setting Up An XL8 System This chapter shows you how to set up an XL8 Live Performance System to its default configuration. Note: If you want to set up the XL8 Live Performance System using a configuration other than the default, please contact Midas Technical Support for details. Initial set-up procedure Initial system set-up basically comprises: •...
Appendix F: Setting Up An XL8 System Outboard equipment racks To ensure the correct installation and function of the outboard equipment, such as the DL4n1 units and DN9696 recorder, the racks must meet the following general requirements. • Shock mounting (for non-installation environments): The racks must provide adequate shock protection of the units they house by incorporating appropriately- designed shock protection methods, for example, a foam-suspended rack or a frame suspended on anti-vibration mounts etc.
Wiring instructions Stage rack 2 Stage rack 2, also known as the “DL461/DL471 engine rack”, contains the two routers and 10 DSP units. Important: In general, the physical location of the hardware units within each rack is not critical, and alternative configurations are acceptable for different packaging preferences.
Page 70
Appendix F: Setting Up An XL8 System >> To connect the routers to the Stage rack 3 units • Mic splitters: In AES50 audio - bank 1 on the X router, connect sockets 3 and 4 to the AES50 audio - A X sockets on the mic splitters. Repeat for the Y router, using the mic splitters’...
Appendix F: Setting Up An XL8 System XL8 system interconnections This diagram shows the network interconnections for a typical FOH XL8 system. Rear of FOH XL8 Control Centre RAPIDE Connect to both X and Y networks Note: All connections are dual redundant, so the system can operate quite normally using either the X or Y cables.
Page 73
XL8 system interconnections FOH rack Note: For connections specific to the 19” rack units, please refer to their respective operator manuals ID: 1 Config: I/O/D IP: 192.168.36.1 ID: 2 Caution! Config: I/O/D Don’t forget the IP: 192.168.36.2 interconnection between the two routers, as system snake redundancy will be compromised without it.
Appendix F: Setting Up An XL8 System Cable type and function The following table shows the type, terminations and function of the XL8 system’s interconnecting cables. Please read the table in conjunction with the network interconnections diagram on page 54. Cable From Description...
Powering the XL8 system Powering the XL8 system The following details the recommended power up and power down procedures for the XL8 system. >> To power up the XL8 system Important Note: DO NOT switch on the speaker sub-system until after the start-up of the XL8 system has been completed.
Appendix F: Setting Up An XL8 System Switching the XL8 Control Centre on/off Carry out the following to switch the XL8 Control Centre on/off in a safe manner, observing all WARNINGS and Cautions. >> To switch on the XL8 Control Centre WARNING! DO NOT INSERT OR REMOVE A POWERCON®...
Setting up the ID of the DL4n1 units >> To switch off the XL8 Control Centre Make sure you have saved any shows, scenes or settings you require (see “Saving your show files to a USB memory stick” on page 56). At the GUI, choose home Preferences Shutdown System.
Page 78
Appendix F: Setting Up An XL8 System DL431 Mic Splitter Operator Manual...
Page 79
Thank you for reading through this Operator Manual. We hope you found it useful. Please feel free to send us your comments. More detailed information on the XL8 can be found in the XL8 Live Performance System Owner’s Manual (part number DOC02-XL8). This is available for download from our website.
Page 80
Midas Klark Teknik Limited Klark Industrial Park, Walter Nash Road, Kidderminster. Worcestershire. DY11 7HJ. England. Tel: +44 1562 741515, Fax: +44 1562 745371 Email: info@midasklarkteknik.com Website: www.midasconsoles.com...
Need help?
Do you have a question about the XL8 DL431 and is the answer not in the manual?
Questions and answers