Crestron iLux CLS-C6 Series Operation Manual page 79

Integrated lighting system
Hide thumbs Also See for iLux CLS-C6 Series:
Table of Contents

Advertisement

Crestron CLS-C6/C6M & CLSI-C6/C6M
Operations Guide – DOC. 6347E
Function name
Toggle Scene (on, 1-15)
Behavior
Alternates between "Recall Scene" and "Turn Off Scene Lights" actions
for the specified scene. In determining which action should be executed,
the CLS-C6 checks the state of all lights programmed in the scene. If
any light in the scene is on, this function causes the lights to go off. If all
lights in the scene are off, this function recalls the scene.
LED
Flash while lights are actively fading (either direction). On when any
light in scene is on, while not fading.
Applies To
Standard Rocker, Shifted Rocker, Remote Button
Rocker
If the "Enable Raise/Lower on Scene Recall Buttons" option is set, then
Behavior
the right and left rockers perform "Scene Raise" and "Scene Lower"
functions, whether or not scene feedback LED for that button is lit. To
toggle the scene, center of button must be pressed.
If the "Enable Raise/Lower on Scene Recall Buttons" option is not set,
then the right, left, and center press all do the same thing.
Notes
Toggle function intended only for scenes that do not affect shades.
Function name
Raise Lighting Load (1-6)
Behavior
The specified lighting load raises as long as the button is held – it stops
when button released. Rate is the global ramp rate.
If they hit the High End limit, the lights stop at that point, but the bar
graph display continues to rise. If going up from OFF, lights immediately
go to the Low End limit, and the bar graph display starts rising from 0.
When the display (i.e.: the internal ramp value) reaches the Low End
limit, the light start moving up in sync.
For non-dim load, lights immediately go to full on.
LED
On while button is pressed
Applies To
Remote Button
Rocker
N/A
Behavior
Notes
This is same as pressing the right side of front panel function button
when in Lights Mode.
Function name
Lower Lighting Load (1-6)
Behavior
Specified lighting load lower as long as button is held –stop when button
is released. Rate is the global ramp rate.
If loads hit the Low End limit, the bar graph continues to go down, but
lights stays at Low End limit level until reach OFF – at which point they
turn off.
If starting from above the High End limit, the bar graph starts to go
down, but lights stay at High End limit level until display reaches the
High End limit – then the light and bar graph starts moving in sync.
For non-dim load, lights immediately go to full off.
LED
On while button is pressed
Applies To
Remote Button
Rocker
N/A
Behavior
Notes
This is same as pressing the left side of front panel function button
when in Lights Mode.
iLux Integrated Lighting System: CLS-C6/C6M & CLSI-C6/C6M • 75
iLux Integrated Lighting System

Hide quick links: