Crestron CLS-C6/C6M & CLSI-C6/C6M

Appendix E: Button Functions

Operations Guide – DOC. 6347E
Following is a list of button functions, in table format, one function per table. Each
table lists Behavior, LED Action, Applies to, Rocker behavior, and Notes. Some
topics may not apply to certain button types; this is defined in the "Applies to" row.
There are four classes of buttons to be considered:
Standard Rocker: the six function buttons on the front panel of the CLS-C6,
while the CLS-C6 is in Standard mode and the shift flag is not set.
Shifted Rocker: the same physical buttons as the Standard Rocker, but are
active when the shift flag is set.
Up/Down Rocker: this is the vertical button on the face of the CLS-C6.
Remote Button: the single-action (i.e. non-rocker) buttons located on remote
keypads.
Function name
Recall Scene (off, on, 1-15)
Behavior
Fades specified lights to specified levels in the specified time. (Non-dim
loads switch at the beginning or end of the specified time, as
determined by the Load Type option for each load.)
Also, sends specified shades to specified positions, (the time is
determined by the motor).
Note that the off scene is special in that it cannot specify which lighting
loads are affected, or what their target levels should be – all lighting
loads go to full off (definitely causing air-gap relay to open). Fade time
and shade behavior can still be specified.
LED action
Flash while lights are actively fading, Scene-interlocked* afterwards.
(Note that for Recall Off Scene, LED is on when all lights are off.)
*LED goes on when scene is recalled. LED remains on until another
scene is recalled (or Lights_in_Scenex_Off is executed) which has
overlapping lighting load or shade group programming. That is, a scene
which affects at least one common lighting load or shade group.
Applies to
Standard Rocker, Shifted Rocker, Remote Button
Rocker
If the "Enable Raise/Lower on Scene Recall Buttons" option is set in
behavior
iLux Designer, the right and left rockers perform "Scene Raise" and
"Scene Lower" functions if, and only if, the scene feedback LED for that
button is lit.
If the "Enable Raise/Lower on Scene Recall Buttons" option is not set,
then the right, left, and center press all do the same thing.
The ON and OFF buttons always recall the On and Off Scene,
Notes
respectively. The assigned functions cannot be changed.
Function name
Turn Off Scene Lights (on, 1-15)
Behavior
Same as Recall Scene button, except:
a) All lights affected by the scene go to off level.
b) Shades are not affected.
Note that the list of unaffected lighting loads and the fade time are the
same as for the Recall Scene function.
LED
Flash while lights are fading, off when fade is done.
Applies To
Remote Button
Rocker
N/A
Behavior
Notes
N/A