Crestron CLS-C6/C6M & CLSI-C6/C6M
Operations Guide – DOC. 6347E
Connectors, Controls, & Indicators (Continued)
#
CONNECTORS
CONTROLS, &
INDICATORS
8
Lights
Button and LED
9
Shades
Button and LED
10
^, v, Save, and Cancel
Buttons
11
Reset Button
12
Shift LEDs
13
Up/Down Push button
ON Button
14
15
OFF Button
LOAD1 – LOAD6
16
HOT, NEUTRAL,
17
(Ground)
18
CONTROL SYSTEM
G Z
Y 24
19
LOCAL DEVICES
G Z
Y 24
*
Interface connectors for CONTROL SYSTEM and LOCAL DEVICES ports are provided with the
unit.
iLux Integrated Lighting System: CLS-C6/C6M & CLSI-C6/C6M • 9
iLux Integrated Lighting System
*
,
DESCRIPTION
Use this switch to select the Lights mode. The LED
illuminates when the mode is selected. Refer to
"Lights Mode" on page 38 for details.
Use this switch to select the Shades mode. The
LED illuminates when the mode is selected. Refer
to "Shades Mode" on page 39 for details.
Use these push buttons to navigate and execute
setup functions. The Save and Cancel LEDs
indicate when these functions are active. Refer to
"Setup Mode" on page 12 for details.
If the unit stops functioning and does not respond to
button pushes, use a thin object such as a paperclip
to activate this switch. The unit reboots (all lighting
loads go off, the two-digit display shows "– –," and
all lighting loads go to their previous state).
These LEDs are covered by the label strip, but are
easily visible through the strip when they are
illuminated. When the Shift mode is enabled via
programming, there can be two functions defined
for each of the six function buttons. The unit must
always be in "upper" or "lower" Shift mode as
indicated by the state of the LEDs.
This three position "rocker" switch is programmable
for master lights control (all lights or last scene),
master shade control, or as a "shift" button to allow
a second set of functions for the six function
buttons.
The ON button always acts as a recall scene button
for the "On" scene. Refer to "Standard Mode" on
page 33 for details.
The OFF button always acts as a recall scene
button for the Off scene, which always turns all
lighting loads off and open the air-gap relay. Refer
to "Standard Mode" on page 33 for details.
Use these terminals to connect the CLS-C6 dimmer
channel outputs to the appropriate lighting loads.
Use these terminals to connect the unit to the 120V
(CLS-C6/M) or 230V (CLSI-C6/M) AC power
source.
Use this 4-pin terminal block to connect the
CLS-C6, using standard Cresnet wiring, to a
2-Series control system network. In this
configuration, the CLS-C6 acts as a standard
Cresnet slave device. (The CLS-C6 does not draw
power from Cresnet.).
Use this 4-pin terminal block to connect the
CLS-C6, using standard Cresnet wiring, to local
devices. In this configuration, the CLS-C6 acts as
the Cresnet Master.