Crestron iLux CLS-C6 Series Operation Manual page 18

Integrated lighting system
Hide thumbs Also See for iLux CLS-C6 Series:
Table of Contents

Advertisement

Crestron CLS-C6/C6M & CLSI-C6/C6M
Operations Guide – DOC. 6347E
displayed value is be saved, but the light level is limited to the programmed
limits.
If a lighting load is defined as an "unused" load type, the bar graph for that
lighting load has all LEDs off. If the lighting load is adjusted, the two-digit
display shows "Er."
To mark a lighting load as "not affected" (i.e., the lighting load's current
state is not be changed by recalling the scene), press and hold the center of
the corresponding button for 3 seconds. Adjustments made to such lighting
loads cancel the "not affected" condition and start adjusting from the
current light level.
While adjustments are being made to the lights or shades, the two-digit
display shows the level, just like in Manual mode. The level for loads that
are not affected are shown as "—." In Manual mode, the display goes blank
after 3 seconds; in this mode, it returns to the "Sc. ##" display.
For SDC (or SDC-DC) shades, when the left or right side of the button is
pressed, the two-digit display immediately shows full open or full closed as
soon as the shade starts moving, and the preset is set to this full open or
closed position even if the shade is stopped before reaching the full open or
full close position.
The iLux Designer or SIMPL programs can lock a scene to prevent it from
being changed using the front panel controls. If the selected scene is
"locked" in the configuration, when an adjustment is made, "Er" is
displayed for 3 seconds, and the scene remains in its existing state.
To adjust the fade time, while "Sc. ##" is displayed, press the ^ and v
buttons to adjust the time. The first time a button is pressed, current fade
time is shown, but not changed. Subsequent presses change the displayed
value. Adjustment to fade time can be made when either Lights mode or
Shades mode is active.
When increasing the time, the value goes from 0 seconds to 59 seconds, and
then 1 minute to 99 minutes. When decreasing the tiem, the value goes from
99 minutes to 1 minute, and then 59 seconds to 0 seconds.
To save or cancel levels, press the Save button to save the new values and
return to Standard mode. Press the Cancel button to return to Standard
mode without saving – previously saved scene parameters are remembered.
Setup Lighting Load Types (Ld)
To set the load types for each lighting load, first enter Setup mode and scroll to the
"Ld" option. The bar graphs immediately indicate the currently selected load type for
each lighting load. Use the function buttons to change the load type, each load type
indicated by a pattern of bar graph segments and a number on the two-digit display,
as shown in the following table. Press the right and left side of the buttons to cycle
through the available load types.
iLux Integrated Lighting System: CLS-C6/C6M & CLSI-C6/C6M • 14
iLux Integrated Lighting System

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents