Timer/Counter1 Dead Time A - Dt1A; Timer/Counter1 Dead Time B - Dt1B - Atmel ATtiny25 Manual

Microcontroller with 2/4/8k bytes in-system programmable flash
Table of Contents

Advertisement

15.2

Timer/Counter1 Dead Time A - DT1A

15.3

Timer/Counter1 Dead Time B - DT1B

7598H–AVR–07/09
Bit
7
$25 ($45)
DT1AH3
DT1AH2
Read/Write
R/W
Initial value
0
The dead time value register A is an 8-bit read/write register.
The dead time delay of is adjusted by the dead time value register, DT1A. The register consists
of two fields, DT1AH3..0 and DT1AL3..0, one for each complementary output. Therefore a differ-
ent dead time delay can be adjusted for the rising edge of OC1A and the rising edge of OC1A.
• Bits 7..4- DT1AH3..DT1AH0: Dead Time Value for OC1A Output
The dead time value for the OC1A output. The dead time delay is set as a number of the pres-
caled timer/counter clocks. The minimum dead time is zero and the maximum dead time is the
prescaled time/counter clock period multiplied by 15.
• Bits 3..0- DT1AL3..DT1AL0: Dead Time Value for OC1A Output
The dead time value for the OC1A output. The dead time delay is set as a number of the pres-
caled timer/counter clocks. The minimum dead time is zero and the maximum dead time is the
prescaled time/counter clock period multiplied by 15.
Bit
7
$25 ($45)
DT1BH3
DT1BH2
Read/Write
R/W
Initial value
0
The dead time value register Bis an 8-bit read/write register.
The dead time delay of is adjusted by the dead time value register, DT1B. The register consists
of two fields, DT1BH3..0 and DT1BL3..0, one for each complementary output. Therefore a differ-
ent dead time delay can be adjusted for the rising edge of OC1A and the rising edge of OC1A.
• Bits 7..4- DT1BH3..DT1BH0: Dead Time Value for OC1B Output
The dead time value for the OC1B output. The dead time delay is set as a number of the pres-
caled timer/counter clocks. The minimum dead time is zero and the maximum dead time is the
prescaled time/counter clock period multiplied by 15.
• Bits 3..0- DT1BL3..DT1BL0: Dead Time Value for OC1B Output
The dead time value for the OC1B output. The dead time delay is set as a number of the pres-
caled timer/counter clocks. The minimum dead time is zero and the maximum dead time is the
prescaled time/counter clock period multiplied by 15.
6
5
4
DT1AH1
DT1AH0
R/W
R/W
R/W
0
0
0
6
5
4
DT1BH1
DT1BH0
R/W
R/W
R/W
0
0
0
ATtiny25/45/85
3
2
1
DT1AL3
DT1AL2
DT1AL1
R/W
R/W
R/W
0
0
0
3
2
1
DT1BL3
DT1BL2
DT1BL1
R/W
R/W
R/W
0
0
0
0
DT1AL0
DT1A
R/W
0
0
DT1BL0
DT1B
R/W
0
95

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Attiny45Attiny85

Table of Contents