Changeover from STRUC V4.x to D7-SYS

4.6.4 Compiling and loading the user program

4-30
in STRUC V.4.x
in D7-SYS
Compile the master
Check the hardware configuration for consistency.
program (MP-
In the HWConfig:
COMP)
Select the menu command Station > Check
consistency.
Compile the
Not necessary as individual step (refer below)
function packages
(FP-COMP)
Compile the
Not necessary as individual step (refer below)
processor program
(PN-COMP)
Compile the
Compile the user program of a CPU
selected processor
In the CFC:
program
Place the chart window of the CPU to be compiled in the
(AUTOCOMP)
foreground. Select the menu command Chart > Compile.
All of the charts of this CPU are compiled and are then
linked with the hardware configuration, which has been
checked for consistency as well as the code libraries to
form a runnable user program. In so doing, a map listing
of the user program is generated. You will be able to
identify the path names of the map listing from the
compilation protocol.
Create the address
In the CFC:
book (OPTIONS
Select the menu command Extras > Settings > Compile
address book)
and select the "Create address book" option in the dialog
window which opens.
When compiling the user program (menu command Chart
> Compile) an address book is automatically generated
for this CPU. You will be able to identify the path names of
the address book file from the compilation protocol.
Load the program
Loading the user program offline
module (PROG -
In the CFC:
selected PN)
Select the menu command Target system > Load. Select
the "Offline" option in the dialog window which
subsequently opens, and then depress "Load":
The compiled user program, and if relevant, the
SIMADYN D operating system are loaded into the memory
module. This memory module is then inserted into the
PCMCIA slot of your PC.
Download (PROG
Loading the user program online
download)
In the CFC:
Select the Target system > Load menu command. In the
dialog window which opens, select the "Online" option
and then depress "Load":
The compiled user program, and if relevant the
SIMADYN D operating system are loaded into the CPU
memory module via a communications link.
Table 4-23
Compiling and loading the user program
System- and communication configuring D7-SYS - SIMADYN D
Edition 03.2001