Siemens SIMADYN D Manual page 493

System- and communication configuring
Hide thumbs Also See for SIMADYN D:
Table of Contents

Advertisement

Connec-
tion
FCS.ARC
Rated DC motor field current [A]
Condition: RRC ≥ ARC ≠ 0,
FCS.NF
Normalization factor to interpret the setpoint
FCS.T
Delay when switching-in and switching-out
Condition: 0 ≤ T ≤ 100000 ms,
SOL.WCL Switch-in threshold for the torque direction (absolute value)
SOL.TH0
Thyristor hold-off time [ms]
Condition: 0.5 ms ≤ TH0 ≤ 131 ms, > YW2\bit 10 =1
SOL.TCP
Thyristor pulse suppression time [ms]
Condition: 0.0 ms ≤ TH0 ≤ 20000 ms ,
SOL.TCD
Monitoring time, torque change M1 ⇔ M2
SOL.TM0
Monitoring time, torque direction M0
PC6.LMP
Main pulse length [ms]
PC6.LFP
Second pulse length [ms]
PC6.AQL
Test operation: Firing angle setpoint [ ° ]
PC6.AWS Shift to INV. op.: Firing angle setpoint [ ° ]
Condition: 90 ≤ AWS ≤ 180,
PC6.DAG
Max. angular change/TA in the direction of rectifier op.
Condition: 0 ≤ DAG ≤ 180,
PC6.DAW Max. angular change/TA in the direction of inverter op.
Condition: 0 ≤ DAW ≤ 180,
CPC.VCI
Current setpoint at the discontinuous limit, {0 < VCI <
discontinuous limit}
CPC.ALP
Pre-control angle in the discontinuous range [ ° ],
{ ≥ 25° ... 30° ≤ }
starts when current starts to flow
CSP.GLI
Gradient for setpoint smoothing
CSP.IL
Gradient for integrator inhibit
Limit values
Connec-
tion
CAV.CX1
Max. current for torque direction M1 (abs. value)
CAV.CX2
Max. current for torque direction M2 (abs. value)
CPI.CLU
Limit of the current-dependent inverter stability limit [ ° ]
CPI.ALU
Inverter control limit of the firing angle [ ° ]
CPI.ALL
Rectifier control limit of the firing angle [ ° ]
PA6.NAZ
No. of failed line supply periods
Condition: 0 ≤ NAZ ≤ 3050,
PA6.NEP
No. of line supply periods
Condition: 0 ≤ NEP ≤ 5000,
System- and communication configuring D7-SYS - SIMADYN D
Edition 06.2002
Significance
> QSF\bit 12 = 1
> QSF\bit 12 = 1.
> YW2\bit10 =1
{ < 45[ ° ] el. }
{ < 45[ ° ] el. }
> QSF\bit 9 = 1
> QSF\bit 9 = 1
> QSF\bit 9 = 1
Significance
> QSF\bit 9 = 1
> QSF\bit 9 = 1
Closed-loop thyristor current control
Value
Value
change
0.0
1.0
1500 ms
0.01
10 ms
20 ms
1000 ms
2000ms
1.1ms
1.1ms
150
150
60
150
0.1
25.0
0.6
0.6
Value
Value
change
0.1
0.1
150.0
150.0
30.0
8
5
Type
Init
Init
Init
Init
Init
Type
Init
Init
Init
Init
5-53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7-sys

Table of Contents