Communications configuring
New component
3-208
Fig. 3-90
Setting the properties
The following settings should be made:
These properties cannot be changed at a later time and have a gray
background.
• D7-SYS version
List box, in which the version is specified for which the components
should be generated
• Component type
List box with the fixed entries "USER", "IT1" and "IT2". "USER" is the
default value
The entries have the following significance:
− USER = Component file generated by the user,
e.g. table files
− IT1/IT2 = System component file for ITSP modules
• Type description
List box with the "Table REAL" and "Table DINT" entries. "Table
REAL" is the default value for the "USER" component type. "Table
DINT" is used for tables in the DINT format.
The entries have the following significance:
− REAL table: Table file with REAL data type
− DINT table: Table file with double integer data type
A new type description can be entered in the list box and
acknowledged using RETURN. This new type description is then
transferred into the list box and can be selected from the list box the
next time.