Closed-loop thyristor current control
Connecting cable,
firing pulses (X1)
5-72
Connection 1:1
Pair No.
1
2
3
4
5
6
7
8
9
10
11
12
13
(contact Z
with contact Z
2
1) 2 x shell-type enclosure A with catches:
Order No.:A09060480501 GDS A-FL
Manufacturer: Harting
2) 2 x insulating bodies for crimp connection:
Order No.:A09060483201 (48 pin)
Manufacturer: Harting
3) Control cable 13 x 2 x 0.18:
Order No.:6FC9343-0AC
Manufacturer: Siemens
4) 2 x cable LIY 1 x 0.5 / 1.6 ws:
(shield connection)
5) Spring-mounted contacts to crimp:
Order No.:09060006421 Crimp
Manufacturer: Harting
Contact assignment
Z
is cable, 4) is shield connection
2
Core A
d4
d6
d8
d10
d12
d14
d20
d22
d24
d26
d28
d30
Not assigned
)
2
System- and communication configuring D7-SYS - SIMADYN D
Core B
b4
b6
b8
b10
b12
b14
b20
b22
b24
b26
b28
b30
Edition 06.2002