Assigning system diagnostics/data transfer list to the slave PROFIBUS address
System- and communication configuring D7-SYS - SIMADYN D
Edition 12.2003
• The 8 words are bit-coded.
• Each bit is assigned a slave with its PROFIBUS address
corresponding to the following table.
• If the bit for the associated slave is set, then the slave has provided
diagnostics data.
Bit 15
Bit 14
...
14
13
...
30
29
110
109
-
(125)
...
SEL=127: Data transfer list
• The data transfer list provides an overview of the slaves which were
involved with data transfer within a configured time
(COM PROFIBUS).
• The 8 words are bit-coded as for the system diagnostics.
• If the bit for the assigned slave is set, then data is being transferred.
SEL=128: Master status
• Outputs information specific to the master (for users, the low byte of
D01 is relevant; the significance of the other outputs has been
documented, but hasn't been explained in any more detail):
Output
D01
low byte
high byte Ident No. SS52 (high byte)=80h
D02
low
high
D03...D08
Table 3-24
Information specific to the master
SEL=3 ... 123: Slave diagnostics
• Output of slave diagnostics data.
• The SEL data entry corresponds to the slave PROFIBUS address.
Communications configuring
Bit 5
Bit 4
4
3
20
19
100
99
116
115
Significance
Status of the DP master: Stop (40h), Clear (80h),
Operate (C0h)
Ident No. SS52 (low byte)=37h
(irrelevant)
Bit 3
Bit 2
Bit 1
(2)
(1)
(0)
18
17
16
...
98
97
96
114
113
112
3-55