Siemens SIMADYN D Manual page 168

System- and communication configuring
Hide thumbs Also See for SIMADYN D:
Table of Contents

Advertisement

Fig. 3-34
"Configuring" window
Fig. 3-35
"Configuring" window
Fig. 3-36
Window, "DP master system, PROFIBUS address"
System- and communication configuring D7-SYS - SIMADYN D
Edition 12.2003
− ET 200 B
Compact type of construction with eight digital outputs and eight
digital inputs: One byte in the transmit telegram and one byte in the
receive telegram. The IDs are specified by the module selection.
− SIMOVERT Master Drive
Slave with intrinsic intelligence: Depending on the drive converter
setting, five different telegram structures (PPO types) are
permitted. These must be defined when configuring and can no
longer be changed. (Fields have a grey background and are
therefore inactive)
5. After configuring has been completed, the display should look like this: